2018•Food Science and Applied BiotechnologyOpen access

Amperometric sensing of hydrogen peroxide using glassy carbon electrode modified with rhodium

Totka Dodevska, Yanna Lazarova

Open full text 3 citations

Abstract

Following our previous studies on the catalytic activity of electrochemically deposited on glassy carbon Rh electrocatalyst towards the reduction of hydrogen peroxide (H2O2), the electrochemical behaviour of the modified electrode was studied by means of cyclic voltammetry and chronoamperometry at pH-values from 5.0 to 9.0. The modified electrode exhibited a rapid, sensitive and reproducible response for the quantitative determination of H2O2 at low applied potential. Amperometry carried out at constant potential of 0 V (vs. Ag/AgCl, 3M KCl) at pH 6.0 (25 oC) gave the following operational parameters: detection limit of 4 μM, linear dynamic range 0.01 – 5.5 mM and electrode sensitivity of 377 μA mM−1 cm−2 .

Open-access reader

About this research paper

What this paper is about

Following our previous studies on the catalytic activity of electrochemically deposited on glassy carbon Rh electrocatalyst towards the reduction of hydrogen peroxide (H2O2), the electrochemical behaviour of the modified electrode was studied by means of cyclic voltammetry and chronoamperometry at pH-values from 5.0 to 9.0. The modified electrode exhibited a rapid, sensitive and reproducible response for the quantitative determination of H2O2 at low applied potential. Amperometry carried out at constant potential of 0 V (vs. Ag/AgCl, 3M KCl) at pH 6.0 (25 oC) gave the following operational parameters: detection limit of 4 μM, linear dynamic range 0.01 – 5.5 mM and electrode sensitivity of 377 μA mM−1 cm−2 .

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Following our previous studies on the catalytic activity of electrochemically deposited on glassy carbon Rh electrocatalyst towards the reduction of hydrogen peroxide (H2O2), the electrochemical behaviour of the modified electrode was studied by means of cyclic voltammetry and chronoamperometry at pH-values from 5.0 to 9.0. The modified electrode exhibited a rapid, sensitive and reproducible response for the quantitative determination of H2O2 at low applied potential. Amperometry carried out at constant potential of 0 V (vs. Ag/AgCl, 3M KCl) at pH 6.0 (25 oC) gave the following operational parameters: detection limit of 4 μM, linear dynamic range 0.01 – 5.5 mM and electrode sensitivity of 377 μA mM−1 cm−2 .

Key concepts: Chronoamperometry, Amperometry, Electrocatalyst, Glassy carbon, Cyclic voltammetry, Hydrogen peroxide, Electrochemistry, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Amperometric sensing of hydrogen peroxide using glassy carbon electrode modified with rhodium — Research Paper | ScholarLens