Shaking table test and numerical simulation on vibration control effects of TMD with different mass ratios on a super high‐rise structure
Zheng Lu, Hengrui Zhang, Bin Zhao, Xianjie Li
Abstract
Zheng Lu, Hengrui Zhang, Bin Zhao, Xianjie Li
Abstract
Summary In this paper, the influence of mass ratio on the vibration control effects of tuned mass damper (TMD) on a super high‐rise building has been investigated. A 1/45 scaled model of a super high‐rise building was constructed, and the TMD with the mass ratio of 0.01, 0.02, and 0.03, respectively, was suspended on the top. Shaking table test and the corresponding numerical simulation were carried out to make a further understanding of the damping mechanism. The structural performance with or without TMD was comparatively studied. The results show that larger mass ratio can improve the control effects under frequent earthquake, but the control effects increase little with the increase of mass ratio under rare earthquake due to structural damages, accompanied by stiffness degradation and nonlinear behavior of the main structure. In addition, some suggestions on the mass ratio selection are also proposed to generalize its applications.
OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Summary In this paper, the influence of mass ratio on the vibration control effects of tuned mass damper (TMD) on a super high‐rise building has been investigated. A 1/45 scaled model of a super high‐rise building was constructed, and the TMD with the mass ratio of 0.01, 0.02, and 0.03, respectively, was suspended on the top. Shaking table test and the corresponding numerical simulation were carried out to make a further understanding of the damping mechanism. The structural performance with or without TMD was comparatively studied. The results show that larger mass ratio can improve the control effects under frequent earthquake, but the control effects increase little with the increase of mass ratio under rare earthquake due to structural damages, accompanied by stiffness degradation and nonlinear behavior of the main structure. In addition, some suggestions on the mass ratio selection are also proposed to generalize its applications.
Key concepts: Tuned mass damper, Mass ratio, Earthquake shaking table, Damping ratio, Structural engineering, Stiffness, Vibration, Vibration control