The Effect of Amplitude Modulation Index and Frequency Modulation Index on Total Harmonic Distortion in 1-Phase Inverter
Nanang Ismail, Akhbar Permadi, Agus Risdiyanto, Bambang Susanto, Muhammad Ali Ramdhani
Abstract
Open-access reader
Nanang Ismail, Akhbar Permadi, Agus Risdiyanto, Bambang Susanto, Muhammad Ali Ramdhani
Abstract
Open-access reader
One of the problems that often arise in the conversion process using an inverter is the existence of Total Harmonic Distortion (THD). Harmonics is a symptom of sinusoidal wave formation whose frequency is a multiple of fundamental frequency. Harmonics will cause interference to the system to damage to electrical devices. This paper discusses the effect of modulation index value amplitudo ( M a ) and frequency modulation index ( M f ) of the value of THD before using the filter. The test was performed using a 1 phase inverter with input variation of the amplitude modulation index and the frequency that was set using PSIM software. The 16 ATMega microcontroller is used as a pulse width modulation (PWM) signal generator. Simulations using a 6 variations value Ma, ie 0.4, 0.6, 0.8 1.0, 1.2, and 1.4, as well as 10 variations of the value of M f , namely 10, 20, 30, 40, 50, 60, 70, 80, 90, and 100. Based measurement, for M f are the same, the greater the value of M a , then the value of THD tends to decrease. Meanwhile, for the same M a , the greater the value of M f , then the value of THD tends to decrease.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
One of the problems that often arise in the conversion process using an inverter is the existence of Total Harmonic Distortion (THD). Harmonics is a symptom of sinusoidal wave formation whose frequency is a multiple of fundamental frequency. Harmonics will cause interference to the system to damage to electrical devices. This paper discusses the effect of modulation index value amplitudo ( M a ) and frequency modulation index ( M f ) of the value of THD before using the filter. The test was performed using a 1 phase inverter with input variation of the amplitude modulation index and the frequency that was set using PSIM software. The 16 ATMega microcontroller is used as a pulse width modulation (PWM) signal generator. Simulations using a 6 variations value Ma, ie 0.4, 0.6, 0.8 1.0, 1.2, and 1.4, as well as 10 variations of the value of M f , namely 10, 20, 30, 40, 50, 60, 70, 80, 90, and 100. Based measurement, for M f are the same, the greater the value of M a , then the value of THD tends to decrease. Meanwhile, for the same M a , the greater the value of M f , then the value of THD tends to decrease.
Key concepts: Total harmonic distortion, Modulation index, THD analyzer, Inverter, Harmonics, Pulse-width modulation, Pulse-frequency modulation, Modulation (music)