1980•Defense Technical Information Center (DTIC)Requires access

National Dam Inspection Program. Sand Spring Run Dam. (NDS I.D. Number PA 00614, DER I.D. Number 13-90), Delaware River Basin, Sand Spring Run, Carbon County, Pennsylvania. Phase I Inspection Report,

Mary F. Beck, John H. Frederick

Open publisher page 0 citations

Abstract

Sand Spring Run Dam is a recreational structure located in Hickory Run State Park and owned by the Commonwealth of Pennsylvania. The visual inspection and review of design and construction documentation indicate that the embankment and outlet structure are in good condition, the concrete weir is in fair condition, and the vegetation is in poor condition. The overall assessment is considered to be fairly good at the present time. In accordance with criteria established by Federal (OCE) Guidelines, the recommended spillway design flood for this 'Small' size dam and 'Significant' hazard potential classification is the 100 Year Flood to one-half the Probable Maximum Flood (PMF). As the dam's total capacity in nearer the lower limit of the size classification and because of the limited number of occupied structures downstream, the 100 Year Event would be an adequate spillway design flood. However, one-half the PMF has been used in this case because of the actual spillway capacity. Hydrologic and hydraulic computations presented in Appendix D indicate the spillway is capable of passing the full PMF without overtopping the embankment, resulting in an 'Adequate' spillway classification for this dam.

About this research paper

What this paper is about

Sand Spring Run Dam is a recreational structure located in Hickory Run State Park and owned by the Commonwealth of Pennsylvania. The visual inspection and review of design and construction documentation indicate that the embankment and outlet structure are in good condition, the concrete weir is in fair condition, and the vegetation is in poor condition. The overall assessment is considered to be fairly good at the present time. In accordance with criteria established by Federal (OCE) Guidelines, the recommended spillway design flood for this 'Small' size dam and 'Significant' hazard potential classification is the 100 Year Flood to one-half the Probable Maximum Flood (PMF). As the dam's total capacity in nearer the lower limit of the size classification and because of the limited number of occupied structures downstream, the 100 Year Event would be an adequate spillway design flood. However, one-half the PMF has been used in this case because of the actual spillway capacity. Hydrologic and hydraulic computations presented in Appendix D indicate the spillway is capable of passing the full PMF without overtopping the embankment, resulting in an 'Adequate' spillway classification for this dam.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Sand Spring Run Dam is a recreational structure located in Hickory Run State Park and owned by the Commonwealth of Pennsylvania. The visual inspection and review of design and construction documentation indicate that the embankment and outlet structure are in good condition, the concrete weir is in fair condition, and the vegetation is in poor condition. The overall assessment is considered to be fairly good at the present time. In accordance with criteria established by Federal (OCE) Guidelines, the recommended spillway design flood for this 'Small' size dam and 'Significant' hazard potential classification is the 100 Year Flood to one-half the Probable Maximum Flood (PMF). As the dam's total capacity in nearer the lower limit of the size classification and because of the limited number of occupied structures downstream, the 100 Year Event would be an adequate spillway design flood. However, one-half the PMF has been used in this case because of the actual spillway capacity. Hydrologic and hydraulic computations presented in Appendix D indicate the spillway is capable of passing the full PMF without overtopping the embankment, resulting in an 'Adequate' spillway classification for this dam.

Key concepts: Spillway, Hydrology (agriculture), Flood myth, Culvert, Ditch, Embankment dam, Weir, Spring (device)

Related papers

Back to paper searchBrowse research topicsOriginal source
National Dam Inspection Program. Sand Spring Run Dam. (NDS I.D. Number PA 00614, DER I.D. Number 13-90), Delaware River Basin, Sand Spring Run, Carbon County, Pennsylvania. Phase I Inspection Report, — Research Paper | ScholarLens