2018•International Journal of Sports MedicineRequires access

Perceptually Regulated Exercise Test Allows Determination of V˙O2max and Ventilatory Threshold But Not Respiratory Compensation Point In Trained Runners

Perrine Truong, Grégoire Paul Millet, Boris Gojanovic

Open publisher page 3 citations

Abstract

Abstract This study aimed to investigate the differences in maximal oxygen uptake (V̇O2max) and submaximal thresholds between a standard graded exercise test (GXT) and a perceptually regulated graded exercise test (PRGXT) in trained runners. Eleven well-trained middle- to long-distance runners performed both tests in a randomized order. PRGXT used incremental “clamps” of rating of perceived exertion (RPE) over 10×1-min stages on an automated treadmill equipped with a sonar sensor allowing them to change their running speed instantly and in a natural way. GXT used fixed 1 km.h−1 increment every minute. Ventilatory threshold (VT) and respiratory compensation point (RCP) were determined using ventilatory equivalents. No differences were found in V̇O2max (68.0 (5.3) vs. 69.5 (5.9) ml·min−1·kg−1, p=0.243), minute ventilation (V̇E) (159.4 (35.0) vs. 162.4 (33.7) l·min−1, p=0.175), heart rate (HR) (188.4 (6.9) vs. 190.7 (5.2) bpm, p=0.254) and speed (21.0 (1.7) vs. 21.1 (2.3) km·h-1, p=0.761) between GXT and PRGXT. At VT, there were no significant differences between GXT and PRGXT for any outcome variables. For 8 of 11 subjects, it was not possible to determine RCP from ventilatory equivalent in PRGXT. GXT appears more relevant for a comprehensive gas analysis in trained runners.

About this research paper

What this paper is about

Abstract This study aimed to investigate the differences in maximal oxygen uptake (V̇O2max) and submaximal thresholds between a standard graded exercise test (GXT) and a perceptually regulated graded exercise test (PRGXT) in trained runners. Eleven well-trained middle- to long-distance runners performed both tests in a randomized order. PRGXT used incremental “clamps” of rating of perceived exertion (RPE) over 10×1-min stages on an automated treadmill equipped with a sonar sensor allowing them to change their running speed instantly and in a natural way. GXT used fixed 1 km.h−1 increment every minute. Ventilatory threshold (VT) and respiratory compensation point (RCP) were determined using ventilatory equivalents. No differences were found in V̇O2max (68.0 (5.3) vs. 69.5 (5.9) ml·min−1·kg−1, p=0.243), minute ventilation (V̇E) (159.4 (35.0) vs. 162.4 (33.7) l·min−1, p=0.175), heart rate (HR) (188.4 (6.9) vs. 190.7 (5.2) bpm, p=0.254) and speed (21.0 (1.7) vs. 21.1 (2.3) km·h-1, p=0.761) between GXT and PRGXT. At VT, there were no significant differences between GXT and PRGXT for any outcome variables. For 8 of 11 subjects, it was not possible to determine RCP from ventilatory equivalent in PRGXT. GXT appears more relevant for a comprehensive gas analysis in trained runners.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract This study aimed to investigate the differences in maximal oxygen uptake (V̇O2max) and submaximal thresholds between a standard graded exercise test (GXT) and a perceptually regulated graded exercise test (PRGXT) in trained runners. Eleven well-trained middle- to long-distance runners performed both tests in a randomized order. PRGXT used incremental “clamps” of rating of perceived exertion (RPE) over 10×1-min stages on an automated treadmill equipped with a sonar sensor allowing them to change their running speed instantly and in a natural way. GXT used fixed 1 km.h−1 increment every minute. Ventilatory threshold (VT) and respiratory compensation point (RCP) were determined using ventilatory equivalents. No differences were found in V̇O2max (68.0 (5.3) vs. 69.5 (5.9) ml·min−1·kg−1, p=0.243), minute ventilation (V̇E) (159.4 (35.0) vs. 162.4 (33.7) l·min−1, p=0.175), heart rate (HR) (188.4 (6.9) vs. 190.7 (5.2) bpm, p=0.254) and speed (21.0 (1.7) vs. 21.1 (2.3) km·h-1, p=0.761) between GXT and PRGXT. At VT, there were no significant differences between GXT and PRGXT for any outcome variables. For 8 of 11 subjects, it was not possible to determine RCP from ventilatory equivalent in PRGXT. GXT appears more relevant for a comprehensive gas analysis in trained runners.

Key concepts: Respiratory compensation, Ventilatory threshold, Medicine, Respiratory system, Test (biology), VO2 max, Physical medicine and rehabilitation, Physical therapy

Related papers

Back to paper searchBrowse research topicsOriginal source
Perceptually Regulated Exercise Test Allows Determination of V˙O2max and Ventilatory Threshold But Not Respiratory Compensation Point In Trained Runners — Research Paper | ScholarLens