2017Unpublished venueRequires access

Influence of maximum assistive force of a soft wearable robotic suit on metabolic cost reduction

Shanhai Jin, Shijie Guo, Kazunobu Hashimoto, Motoji Yamamoto

Open publisher page 2 citations

Abstract

Metabolic cost during walking is positively associated with exercise intensity. As a walking assistive device, one of the major goals should be the maximization of wearers' metabolic benefits. Toward this goal, this paper experimentally evaluates the influence of maximum assistive force (MAF) of an authors' soft robotic suit, which has been developed to assist hip flexion for energy-efficient walking of elderly persons in daily activities, on metabolic cost reduction. Experiment results show that, for a 79-years-old healthy male subject, the metabolic cost reduction rate of the soft robotic suit was not linearly correlated with the value of MAF in the condition of the robotic suit worn and powered on (PON) compared with that of worn but powered off (POFF). Instead, it is interestingly observed that the metabolic cost was significantly reduced by an average of -12 % in the PON condition with MAF that the subject felt most comfortable with (24.5 N), while the reduction rates were -0.8 % and -3.1 % in the PON condition with MAFs that the subject felt weak (15.7 N) and strong (29.4 N), respectively, showing no significant differences between the two conditions. The findings of this study are beneficial for the future development of soft robotic suits that assist hip flexion of elderly persons.

About this research paper

What this paper is about

Metabolic cost during walking is positively associated with exercise intensity. As a walking assistive device, one of the major goals should be the maximization of wearers' metabolic benefits. Toward this goal, this paper experimentally evaluates the influence of maximum assistive force (MAF) of an authors' soft robotic suit, which has been developed to assist hip flexion for energy-efficient walking of elderly persons in daily activities, on metabolic cost reduction. Experiment results show that, for a 79-years-old healthy male subject, the metabolic cost reduction rate of the soft robotic suit was not linearly correlated with the value of MAF in the condition of the robotic suit worn and powered on (PON) compared with that of worn but powered off (POFF). Instead, it is interestingly observed that the metabolic cost was significantly reduced by an average of -12 % in the PON condition with MAF that the subject felt most comfortable with (24.5 N), while the reduction rates were -0.8 % and -3.1 % in the PON condition with MAFs that the subject felt weak (15.7 N) and strong (29.4 N), respectively, showing no significant differences between the two conditions. The findings of this study are beneficial for the future development of soft robotic suits that assist hip flexion of elderly persons.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Metabolic cost during walking is positively associated with exercise intensity. As a walking assistive device, one of the major goals should be the maximization of wearers' metabolic benefits. Toward this goal, this paper experimentally evaluates the influence of maximum assistive force (MAF) of an authors' soft robotic suit, which has been developed to assist hip flexion for energy-efficient walking of elderly persons in daily activities, on metabolic cost reduction. Experiment results show that, for a 79-years-old healthy male subject, the metabolic cost reduction rate of the soft robotic suit was not linearly correlated with the value of MAF in the condition of the robotic suit worn and powered on (PON) compared with that of worn but powered off (POFF). Instead, it is interestingly observed that the metabolic cost was significantly reduced by an average of -12 % in the PON condition with MAF that the subject felt most comfortable with (24.5 N), while the reduction rates were -0.8 % and -3.1 % in the PON condition with MAFs that the subject felt weak (15.7 N) and strong (29.4 N), respectively, showing no significant differences between the two conditions. The findings of this study are beneficial for the future development of soft robotic suits that assist hip flexion of elderly persons.

Key concepts: Metabolic cost, Powered exoskeleton, Wearable computer, Reduction (mathematics), Computer science, Exoskeleton, Energy cost, Assistive device

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of maximum assistive force of a soft wearable robotic suit on metabolic cost reduction — Research Paper | ScholarLens