2018•Korean Journal of RadiologyOpen access

Quantitative Image Quality and Histogram-Based Evaluations of an Iterative Reconstruction Algorithm at Low-to-Ultralow Radiation Dose Levels: A Phantom Study in Chest CT

Ki Baek Lee, Hyun Woo Goo

Open full text 30 citations

Abstract

Objective: To describe the quantitative image quality and histogram-based evaluation of an iterative reconstruction (IR) algorithm in chest computed tomography (CT) scans at low-to-ultralow CT radiation dose levels. Materials and Methods:In an adult anthropomorphic phantom, chest CT scans were performed with 128-section dual-source CT at 70, 80, 100, 120, and 140 kVp, and the reference (3.4 mGy in volume CT Dose Index [CTDIvol]), 30%-, 60%-, and 90%-reduced radiation dose levels (2.4,1.4, and 0.3 mGy).The CT images were reconstructed by using filtered back projection (FBP) algorithms and IR algorithm with strengths 1, 3, and 5. Image noise, signal-to-noise ratio (SNR), and contrast-tonoise ratio (CNR) were statistically compared between different dose levels, tube voltages, and reconstruction algorithms.Moreover, histograms of subtraction images before and after standardization in x-and y-axes were visually compared.Results: Compared with FBP images, IR images with strengths 1, 3, and 5 demonstrated image noise reduction up to 49.1%, SNR increase up to 100.7%, and CNR increase up to 67.3%.Noteworthy image quality degradations on IR images including a 184.9% increase in image noise, 63.0% decrease in SNR, and 51.3% decrease in CNR, and were shown between 60% and 90% reduced levels of radiation dose (p < 0.0001).Subtraction histograms between FBP and IR images showed progressively increased dispersion with increased IR strength and increased dose reduction.After standardization, the histograms appeared deviated and ragged between FBP images and IR images with strength 3 or 5, but almost normallydistributed between FBP images and IR images with strength 1. Conclusion: The IR algorithm may be used to save radiation doses without substantial image quality degradation in chest CT scanning of the adult anthropomorphic phantom, down to approximately 1.4 mGy in CTDIvol (60% reduced dose).

Open-access reader

About this research paper

What this paper is about

Objective: To describe the quantitative image quality and histogram-based evaluation of an iterative reconstruction (IR) algorithm in chest computed tomography (CT) scans at low-to-ultralow CT radiation dose levels. Materials and Methods:In an adult anthropomorphic phantom, chest CT scans were performed with 128-section dual-source CT at 70, 80, 100, 120, and 140 kVp, and the reference (3.4 mGy in volume CT Dose Index [CTDIvol]), 30%-, 60%-, and 90%-reduced radiation dose levels (2.4,1.4, and 0.3 mGy).The CT images were reconstructed by using filtered back projection (FBP) algorithms and IR algorithm with strengths 1, 3, and 5. Image noise, signal-to-noise ratio (SNR), and contrast-tonoise ratio (CNR) were statistically compared between different dose levels, tube voltages, and reconstruction algorithms.Moreover, histograms of subtraction images before and after standardization in x-and y-axes were visually compared.Results: Compared with FBP images, IR images with strengths 1, 3, and 5 demonstrated image noise reduction up to 49.1%, SNR increase up to 100.7%, and CNR increase up to 67.3%.Noteworthy image quality degradations on IR images including a 184.9% increase in image noise, 63.0% decrease in SNR, and 51.3% decrease in CNR, and were shown between 60% and 90% reduced levels of radiation dose (p < 0.0001).Subtraction histograms between FBP and IR images showed progressively increased dispersion with increased IR strength and increased dose reduction.After standardization, the histograms appeared deviated and ragged between FBP images and IR images with strength 3 or 5, but almost normallydistributed between FBP images and IR images with strength 1. Conclusion: The IR algorithm may be used to save radiation doses without substantial image quality degradation in chest CT scanning of the adult anthropomorphic phantom, down to approximately 1.4 mGy in CTDIvol (60% reduced dose).

Why it matters

OpenAlex reports 30 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To describe the quantitative image quality and histogram-based evaluation of an iterative reconstruction (IR) algorithm in chest computed tomography (CT) scans at low-to-ultralow CT radiation dose levels. Materials and Methods:In an adult anthropomorphic phantom, chest CT scans were performed with 128-section dual-source CT at 70, 80, 100, 120, and 140 kVp, and the reference (3.4 mGy in volume CT Dose Index [CTDIvol]), 30%-, 60%-, and 90%-reduced radiation dose levels (2.4,1.4, and 0.3 mGy).The CT images were reconstructed by using filtered back projection (FBP) algorithms and IR algorithm with strengths 1, 3, and 5. Image noise, signal-to-noise ratio (SNR), and contrast-tonoise ratio (CNR) were statistically compared between different dose levels, tube voltages, and reconstruction algorithms.Moreover, histograms of subtraction images before and after standardization in x-and y-axes were visually compared.Results: Compared with FBP images, IR images with strengths 1, 3, and 5 demonstrated image noise reduction up to 49.1%, SNR increase up to 100.7%, and CNR increase up to 67.3%.Noteworthy image quality degradations on IR images including a 184.9% increase in image noise, 63.0% decrease in SNR, and 51.3% decrease in CNR, and were shown between 60% and 90% reduced levels of radiation dose (p < 0.0001).Subtraction histograms between FBP and IR images showed progressively increased dispersion with increased IR strength and increased dose reduction.After standardization, the histograms appeared deviated and ragged between FBP images and IR images with strength 3 or 5, but almost normallydistributed between FBP images and IR images with strength 1. Conclusion: The IR algorithm may be used to save radiation doses without substantial image quality degradation in chest CT scanning of the adult anthropomorphic phantom, down to approximately 1.4 mGy in CTDIvol (60% reduced dose).

Key concepts: Imaging phantom, Image quality, Medicine, Nuclear medicine, Image noise, Subtraction, Histogram, Iterative reconstruction

Related papers

Back to paper searchBrowse research topicsOriginal source
Quantitative Image Quality and Histogram-Based Evaluations of an Iterative Reconstruction Algorithm at Low-to-Ultralow Radiation Dose Levels: A Phantom Study in Chest CT — Research Paper | ScholarLens