2005Acta Scientiarum Naturalium Universitatis SunyatseniRequires access

Portal venous stent placement for treatment of portal hypertension caused by benign main portal vein stenosis

Hongshan, Xiang-ShengXiao, Ming-ShengHuang, QiangOuyang, Zai-BoJiang

Open publisher page 0 citations

Abstract

AIM: To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis.METHODS: Portal vein stents were implanted in six patients with benign main portal vein stenosis (inflammatory stenosis in three cases, postprocedure of liver transplantation in another three cases). Changes in portal vein pressure, portal vein patency, relative clinical symptoms, complications, and survival were evaluated.RESULTS: Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in six patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3±4.7) cm H2O to (18.0±1.9) cm H2O. The portal blood flow restoredand the symptoms caused by portal hypertension were eliminated. There were no severe procedure-related complications. The patients were followed up for 1-48 mo. The portal vein remained patent during follow-up. All patients survived except for one patient who died of other complications of liver transplantation. CONCLUSION: Percutaneous portal vein stent placement for the treatment of portal hypertension caused by benign main portal vein stenosis is safe and effective.

About this research paper

What this paper is about

AIM: To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis.METHODS: Portal vein stents were implanted in six patients with benign main portal vein stenosis (inflammatory stenosis in three cases, postprocedure of liver transplantation in another three cases). Changes in portal vein pressure, portal vein patency, relative clinical symptoms, complications, and survival were evaluated.RESULTS: Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in six patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3±4.7) cm H2O to (18.0±1.9) cm H2O. The portal blood flow restoredand the symptoms caused by portal hypertension were eliminated. There were no severe procedure-related complications. The patients were followed up for 1-48 mo. The portal vein remained patent during follow-up. All patients survived except for one patient who died of other complications of liver transplantation. CONCLUSION: Percutaneous portal vein stent placement for the treatment of portal hypertension caused by benign main portal vein stenosis is safe and effective.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AIM: To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis.METHODS: Portal vein stents were implanted in six patients with benign main portal vein stenosis (inflammatory stenosis in three cases, postprocedure of liver transplantation in another three cases). Changes in portal vein pressure, portal vein patency, relative clinical symptoms, complications, and survival were evaluated.RESULTS: Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in six patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3±4.7) cm H2O to (18.0±1.9) cm H2O. The portal blood flow restoredand the symptoms caused by portal hypertension were eliminated. There were no severe procedure-related complications. The patients were followed up for 1-48 mo. The portal vein remained patent during follow-up. All patients survived except for one patient who died of other complications of liver transplantation. CONCLUSION: Percutaneous portal vein stent placement for the treatment of portal hypertension caused by benign main portal vein stenosis is safe and effective.

Key concepts: Medicine, Stenosis, Portal hypertension, Portal venous pressure, Stent, Percutaneous, Radiology, Liver transplantation

Related papers

Back to paper searchBrowse research topicsOriginal source
Portal venous stent placement for treatment of portal hypertension caused by benign main portal vein stenosis — Research Paper | ScholarLens