Graphite Furnace Atomic Absorption Spectrometry After Dispersive Liquid–Liquid Microextraction for the Determination of Selenium in the Anodic Slime
Sayed Zia Mohammadi, Daryoush Afzali, Farzaneh Arabpour
Abstract
Sayed Zia Mohammadi, Daryoush Afzali, Farzaneh Arabpour
Abstract
In the present study, a method based on dispersive liquid–liquid microextraction (DLLME) followed by graphite furnace atomic absorption spectrometry (GFAAS) determination was proposed for the determination of selenium by using ammonium pyrrolidine dithiocarbamate (APDC) as the chelating reagent. The main factors influencing the DLLME were investigated systematically. Under the optimal conditions, the limit of detection for Se(IV) was 0.02 ng mL−1. The relative standard deviation was 4.1% (CSe(IV) = 0.2 ng mL−1, n = 8) with an enhancement factor of 135.8-fold from only 5 mL of the water sample. The proposed method was successfully applied to the determination of Se(IV) in anodic slime and electrolyte samples. In order to validate the proposed method, a Certified Reference Material (trace elements in water, 1643e, NIST) was analyzed, and the determined value obtained was in good agreement with the certified value.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In the present study, a method based on dispersive liquid–liquid microextraction (DLLME) followed by graphite furnace atomic absorption spectrometry (GFAAS) determination was proposed for the determination of selenium by using ammonium pyrrolidine dithiocarbamate (APDC) as the chelating reagent. The main factors influencing the DLLME were investigated systematically. Under the optimal conditions, the limit of detection for Se(IV) was 0.02 ng mL−1. The relative standard deviation was 4.1% (CSe(IV) = 0.2 ng mL−1, n = 8) with an enhancement factor of 135.8-fold from only 5 mL of the water sample. The proposed method was successfully applied to the determination of Se(IV) in anodic slime and electrolyte samples. In order to validate the proposed method, a Certified Reference Material (trace elements in water, 1643e, NIST) was analyzed, and the determined value obtained was in good agreement with the certified value.
Key concepts: Graphite furnace atomic absorption, Selenium, Certified reference materials, Chemistry, Detection limit, Atomic absorption spectroscopy, Chromatography, Graphite