Fast Fatty Acid Analysis by Core-Shell Reversed-Phase Liquid Chromatography Coupled to Evaporative Light-Scattering Detector
Florence Hubert, Céline Loiseau, Françoise Ergan, Gaëlle Pencreach, Laurent Poisson
Abstract
Open-access reader
Florence Hubert, Céline Loiseau, Françoise Ergan, Gaëlle Pencreach, Laurent Poisson
Abstract
Open-access reader
A high-performance liquid chromatography analysis method with an evaporative light-scattering detector has been developed for the separation and quantitative analysis of free fatty acids in biological matrices. Core-shell reversed-phase high-performance liquid chromatography separation of 10 free fatty acids is achieved within 10.5 min using a methanol/water (0.05% trifluoroacetic acid) eluent gradient. After optimization, the drift tube and nebulization temperature of the evaporative light-scattering detector was set at 35°C, nitrogen flow-rate at 1.1 standard liter per minute and column temperature at 25°C. All calibration curves showed good regression (r2 > 0.9975). A validation procedure following the International Conference on Harmonisation guidelines was implemented to certify the method. Relative standard deviations did not exceed 1.5% and 4.25% for repeatability and reproducibility respectively.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A high-performance liquid chromatography analysis method with an evaporative light-scattering detector has been developed for the separation and quantitative analysis of free fatty acids in biological matrices. Core-shell reversed-phase high-performance liquid chromatography separation of 10 free fatty acids is achieved within 10.5 min using a methanol/water (0.05% trifluoroacetic acid) eluent gradient. After optimization, the drift tube and nebulization temperature of the evaporative light-scattering detector was set at 35°C, nitrogen flow-rate at 1.1 standard liter per minute and column temperature at 25°C. All calibration curves showed good regression (r2 > 0.9975). A validation procedure following the International Conference on Harmonisation guidelines was implemented to certify the method. Relative standard deviations did not exceed 1.5% and 4.25% for repeatability and reproducibility respectively.
Key concepts: Detector, Chromatography, Chromatography detector, Phase (matter), Chemistry, High-performance liquid chromatography, Core (optical fiber), Light scattering