2017•Taiwanese Journal of Obstetrics and GynecologyOpen access

The comparison of umbilical cord arterial blood lactate and pH values for predicting short-term neonatal outcomes

Rūta Einikytė, Vilija Sniečkuvienė, Diana Ramašauskaitė, Jurate Panaviene, Virginija Paliulytė, Gina Opolskiene, Edita Kazėnaitė

Open full text 27 citations

Abstract

OBJECTIVE: Current clinical practice of assessing neonatal condition is based on evaluation of umbilical cord arterial blood pH value rather than lactate. However, evidence shows that lactate is direct and more predictive measurement than pH or at least of equal importance. This study is to assess and compare umbilical cord arterial lactate and pH values for predicting short-term neonatal outcomes. MATERIALS AND METHODS: A retrospective cohort study was conducted at the tertiary level hospital, were arterial umbilical cord blood sampling was collected according to the standard procedures. Neonatal morbidity was registered if at least one of the following conditions was noted: Apgar score at 1 min after delivery was 6 or lower, resuscitation performed, including assisted ventilation and requirement of admission to neonatal intensive care unit. Mothers-newborns pairs were allocated into two groups: newborns exposed to perinatal hypoxia (group 1) and observed as healthy newborns (group 2). Receiver operating characteristics curves (ROC) were generated to assess the predictive ability of pH and lactate for the short-term neonatal outcomes. RESULTS: 901 neonates born at ≥37 weeks of gestation were included. Newborns exposed to perinatal hypoxia (group 1) encompassed 39 (4.3%) patients, and observed as healthy (group 2) - 862 (95.7%). Arterial umbilical cord blood pH in group 1 was 7.160 ± 0.126 as compared to 7.314 ± 0.083 in group 2; p < 0.001. Mean arterial lactate was significantly higher in group 1 than group 2 (6.423 ± 2.335 as compared to 3.600 ± 1.833; p < 0.001). The difference between areas under ROC curves representing pH and lactate was not significant (0.848 and 0.831 respectively; p = 0.6132). CONCLUSION: Umbilical cord arterial lactate and pH predicted short-term neonatal outcomes with similar efficacies.

Open-access reader

About this research paper

What this paper is about

OBJECTIVE: Current clinical practice of assessing neonatal condition is based on evaluation of umbilical cord arterial blood pH value rather than lactate. However, evidence shows that lactate is direct and more predictive measurement than pH or at least of equal importance. This study is to assess and compare umbilical cord arterial lactate and pH values for predicting short-term neonatal outcomes. MATERIALS AND METHODS: A retrospective cohort study was conducted at the tertiary level hospital, were arterial umbilical cord blood sampling was collected according to the standard procedures. Neonatal morbidity was registered if at least one of the following conditions was noted: Apgar score at 1 min after delivery was 6 or lower, resuscitation performed, including assisted ventilation and requirement of admission to neonatal intensive care unit. Mothers-newborns pairs were allocated into two groups: newborns exposed to perinatal hypoxia (group 1) and observed as healthy newborns (group 2). Receiver operating characteristics curves (ROC) were generated to assess the predictive ability of pH and lactate for the short-term neonatal outcomes. RESULTS: 901 neonates born at ≥37 weeks of gestation were included. Newborns exposed to perinatal hypoxia (group 1) encompassed 39 (4.3%) patients, and observed as healthy (group 2) - 862 (95.7%). Arterial umbilical cord blood pH in group 1 was 7.160 ± 0.126 as compared to 7.314 ± 0.083 in group 2; p < 0.001. Mean arterial lactate was significantly higher in group 1 than group 2 (6.423 ± 2.335 as compared to 3.600 ± 1.833; p < 0.001). The difference between areas under ROC curves representing pH and lactate was not significant (0.848 and 0.831 respectively; p = 0.6132). CONCLUSION: Umbilical cord arterial lactate and pH predicted short-term neonatal outcomes with similar efficacies.

Why it matters

OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: Current clinical practice of assessing neonatal condition is based on evaluation of umbilical cord arterial blood pH value rather than lactate. However, evidence shows that lactate is direct and more predictive measurement than pH or at least of equal importance. This study is to assess and compare umbilical cord arterial lactate and pH values for predicting short-term neonatal outcomes. MATERIALS AND METHODS: A retrospective cohort study was conducted at the tertiary level hospital, were arterial umbilical cord blood sampling was collected according to the standard procedures. Neonatal morbidity was registered if at least one of the following conditions was noted: Apgar score at 1 min after delivery was 6 or lower, resuscitation performed, including assisted ventilation and requirement of admission to neonatal intensive care unit. Mothers-newborns pairs were allocated into two groups: newborns exposed to perinatal hypoxia (group 1) and observed as healthy newborns (group 2). Receiver operating characteristics curves (ROC) were generated to assess the predictive ability of pH and lactate for the short-term neonatal outcomes. RESULTS: 901 neonates born at ≥37 weeks of gestation were included. Newborns exposed to perinatal hypoxia (group 1) encompassed 39 (4.3%) patients, and observed as healthy (group 2) - 862 (95.7%). Arterial umbilical cord blood pH in group 1 was 7.160 ± 0.126 as compared to 7.314 ± 0.083 in group 2; p < 0.001. Mean arterial lactate was significantly higher in group 1 than group 2 (6.423 ± 2.335 as compared to 3.600 ± 1.833; p < 0.001). The difference between areas under ROC curves representing pH and lactate was not significant (0.848 and 0.831 respectively; p = 0.6132). CONCLUSION: Umbilical cord arterial lactate and pH predicted short-term neonatal outcomes with similar efficacies.

Key concepts: Umbilical cord, Medicine, Arterial pH, Umbilical artery, Cardiology, Term (time), Arterial blood, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
The comparison of umbilical cord arterial blood lactate and pH values for predicting short-term neonatal outcomes — Research Paper | ScholarLens