2017IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics SocietyRequires access

Direct harmonic voltage control strategy for shunt active power filter

Hafiz Mudassir Munir, Jianxiao Zou, Chuan Xie, Kai Li, Xin Zhao, Josep M. Guerrero

Open publisher page 8 citations

Abstract

Shunt active power filters (S-APF) are highly popular ways for harmonic compensation due to the high performance and simplicity of installation. S-APF is commonly controlled in current control mode with load harmonic current detection, which is not quite suitable for the distributed power generation system (DPGS) where the nonlinear loads are highly dispersed. Local harmonic voltage detection based Resistive-APF (R-APF) seems more suitable to be applied in the DPGS, however, R-APF suffers from poor compensation performance and difficulty of parameter tuning. In this paper, a direct harmonic voltage control strategy for the S-APF is proposed with local point of common coupling (PCC) voltage detection only. The control strategy design procedure is given in detail. Simulation is conducted in Matlab/Simulink to compare the performance between the R-APF and the proposed method. The results validate superiority of the proposed method.

About this research paper

What this paper is about

Shunt active power filters (S-APF) are highly popular ways for harmonic compensation due to the high performance and simplicity of installation. S-APF is commonly controlled in current control mode with load harmonic current detection, which is not quite suitable for the distributed power generation system (DPGS) where the nonlinear loads are highly dispersed. Local harmonic voltage detection based Resistive-APF (R-APF) seems more suitable to be applied in the DPGS, however, R-APF suffers from poor compensation performance and difficulty of parameter tuning. In this paper, a direct harmonic voltage control strategy for the S-APF is proposed with local point of common coupling (PCC) voltage detection only. The control strategy design procedure is given in detail. Simulation is conducted in Matlab/Simulink to compare the performance between the R-APF and the proposed method. The results validate superiority of the proposed method.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Shunt active power filters (S-APF) are highly popular ways for harmonic compensation due to the high performance and simplicity of installation. S-APF is commonly controlled in current control mode with load harmonic current detection, which is not quite suitable for the distributed power generation system (DPGS) where the nonlinear loads are highly dispersed. Local harmonic voltage detection based Resistive-APF (R-APF) seems more suitable to be applied in the DPGS, however, R-APF suffers from poor compensation performance and difficulty of parameter tuning. In this paper, a direct harmonic voltage control strategy for the S-APF is proposed with local point of common coupling (PCC) voltage detection only. The control strategy design procedure is given in detail. Simulation is conducted in Matlab/Simulink to compare the performance between the R-APF and the proposed method. The results validate superiority of the proposed method.

Key concepts: Control theory (sociology), Active power filter, Harmonic, Voltage, Compensation (psychology), MATLAB, Electronic engineering, Shunt (medical)