2017Journal of Environmental & Analytical ToxicologyRequires access

Groundwater Assessment through an Integrated Approach Using GIS and Electrical Resistivity Technique: A Case Study from the Bullom Group of Sediments in Sierra Leone

Yaguba Jalloh, Mustapha Olajiday Thomsa, Kyuro Sasaki

Open publisher page 0 citations

Abstract

Electrical Resistivity in conjunction with Geographic Information System (GIS) techniques have been widely used in groundwater resource management. In this research, Vertical Electric Sounding (VES), an Electrical Resistivity method, was integrated with GIS to delineate geo-electric characteristics and evaluate groundwater potential of the Bullom group of sediments in Sierra Leone. For this assessment, a total of 5 vertical electrical sounding stations were established within the site. The Schlumberger electrode configuration and the expanding procedure were used for data acquisition. The VES curves generated were interpreted using partial curve matching. The depth sounding interpretation results were used to generate geo-electric sections from which the aquifer was delineated. The aquifer revealed four subsurface layers which comprises of sandy topsoil, clayey sand which acts as aquitard and sandy gravel (confine aquifer) that serves as a source of portable water in the study area. A GIS model was then developed to locate the suitable groundwater prospective zones which reveals the average depth to groundwater to be between 10 m to 30 m. This research concluded that the boreholes were sited in high conductivity zones in VES layers 1, 2, 3 and 4 as they contain probable aquifers with good yield.

About this research paper

What this paper is about

Electrical Resistivity in conjunction with Geographic Information System (GIS) techniques have been widely used in groundwater resource management. In this research, Vertical Electric Sounding (VES), an Electrical Resistivity method, was integrated with GIS to delineate geo-electric characteristics and evaluate groundwater potential of the Bullom group of sediments in Sierra Leone. For this assessment, a total of 5 vertical electrical sounding stations were established within the site. The Schlumberger electrode configuration and the expanding procedure were used for data acquisition. The VES curves generated were interpreted using partial curve matching. The depth sounding interpretation results were used to generate geo-electric sections from which the aquifer was delineated. The aquifer revealed four subsurface layers which comprises of sandy topsoil, clayey sand which acts as aquitard and sandy gravel (confine aquifer) that serves as a source of portable water in the study area. A GIS model was then developed to locate the suitable groundwater prospective zones which reveals the average depth to groundwater to be between 10 m to 30 m. This research concluded that the boreholes were sited in high conductivity zones in VES layers 1, 2, 3 and 4 as they contain probable aquifers with good yield.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Electrical Resistivity in conjunction with Geographic Information System (GIS) techniques have been widely used in groundwater resource management. In this research, Vertical Electric Sounding (VES), an Electrical Resistivity method, was integrated with GIS to delineate geo-electric characteristics and evaluate groundwater potential of the Bullom group of sediments in Sierra Leone. For this assessment, a total of 5 vertical electrical sounding stations were established within the site. The Schlumberger electrode configuration and the expanding procedure were used for data acquisition. The VES curves generated were interpreted using partial curve matching. The depth sounding interpretation results were used to generate geo-electric sections from which the aquifer was delineated. The aquifer revealed four subsurface layers which comprises of sandy topsoil, clayey sand which acts as aquitard and sandy gravel (confine aquifer) that serves as a source of portable water in the study area. A GIS model was then developed to locate the suitable groundwater prospective zones which reveals the average depth to groundwater to be between 10 m to 30 m. This research concluded that the boreholes were sited in high conductivity zones in VES layers 1, 2, 3 and 4 as they contain probable aquifers with good yield.

Key concepts: Sierra leone, Groundwater, Electrical resistivity and conductivity, Geology, Engineering, Geotechnical engineering, Electrical engineering, Sociology

Related papers

Back to paper searchBrowse research topicsOriginal source
Groundwater Assessment through an Integrated Approach Using GIS and Electrical Resistivity Technique: A Case Study from the Bullom Group of Sediments in Sierra Leone — Research Paper | ScholarLens