Modification of Screen Printed Carbon Electrode (SPCE) with Polypyrrole (Ppy)-SiO2 for Phenol Determination
Erasti Pratiwi, Ani Mulyasuryani, Akhmad Sabarudin
Abstract
Open-access reader
Erasti Pratiwi, Ani Mulyasuryani, Akhmad Sabarudin
Abstract
Open-access reader
Modification of electrodes on a screen printed carbon electrode (SPCE) using polypyrrole (Ppy)-SiO 2 has been successfully conducted for phenol determination.Modification has been undertaken with electropolymerization-wise using cyclic voltammetry.Electrode resulted are used to determine phenol using cyclic voltammetry and differential pulse voltammetry.A cyclic voltammetry analysis using potential range of -1 to 1 V versus Ag/AgCl at scan rate of 100 mV/sec.Meanwhile, analysis using differential pulse voltammetry method applied potential range of 0 to 1 V versus Ag/AgCl, scan rate of 50 mV/sec, pulse rate of 0.2 V, and pulse width of 50 ms.The results provide the increase of pH and decrease of Epa potential peak.It may increase in the current of phenol.Modified SPCE Ppy-SiO 2 can be applied for phenol determination at a concentration of 10 3 -10 -5 mM with sensitivity of 7.93 μA/mM.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Modification of electrodes on a screen printed carbon electrode (SPCE) using polypyrrole (Ppy)-SiO 2 has been successfully conducted for phenol determination.Modification has been undertaken with electropolymerization-wise using cyclic voltammetry.Electrode resulted are used to determine phenol using cyclic voltammetry and differential pulse voltammetry.A cyclic voltammetry analysis using potential range of -1 to 1 V versus Ag/AgCl at scan rate of 100 mV/sec.Meanwhile, analysis using differential pulse voltammetry method applied potential range of 0 to 1 V versus Ag/AgCl, scan rate of 50 mV/sec, pulse rate of 0.2 V, and pulse width of 50 ms.The results provide the increase of pH and decrease of Epa potential peak.It may increase in the current of phenol.Modified SPCE Ppy-SiO 2 can be applied for phenol determination at a concentration of 10 3 -10 -5 mM with sensitivity of 7.93 μA/mM.
Key concepts: Polypyrrole, Differential pulse voltammetry, Cyclic voltammetry, Horizontal scan rate, Chemistry, Electrode, Phenol, Voltammetry