2017•Unpublished venueRequires access

Analysis of grounding grid of substation

Chetan S. Payshetti, Himmat Tukaram Jadhav, Shrihari Kulkarani

Open publisher page 6 citations

Abstract

The grounding system requires for maintaining safety of operators and apparatus and ensuring reliable working of power network. A grounding of substation connects electrical apparatus and the metallic structures to the common ground. Grounding system of substation should be such that it should limit the potential gradients with in and around substation during normal and fault condition. Ground Fault creates potential rise within and around the substation which increases the step and touch potential. These potentials should be less than the permissible human body limit. For examination grounding grid of substation needs to calculate parameters related to earth and grounding for safe operation. In this paper parameters of existing design of grounding grid of substation are calculated with IEEE standard 80-2013 and some techniques are discussed for increasing grounding system safety. ETAP (Electrical power system analysis) software is used for analysis.

About this research paper

What this paper is about

The grounding system requires for maintaining safety of operators and apparatus and ensuring reliable working of power network. A grounding of substation connects electrical apparatus and the metallic structures to the common ground. Grounding system of substation should be such that it should limit the potential gradients with in and around substation during normal and fault condition. Ground Fault creates potential rise within and around the substation which increases the step and touch potential. These potentials should be less than the permissible human body limit. For examination grounding grid of substation needs to calculate parameters related to earth and grounding for safe operation. In this paper parameters of existing design of grounding grid of substation are calculated with IEEE standard 80-2013 and some techniques are discussed for increasing grounding system safety. ETAP (Electrical power system analysis) software is used for analysis.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The grounding system requires for maintaining safety of operators and apparatus and ensuring reliable working of power network. A grounding of substation connects electrical apparatus and the metallic structures to the common ground. Grounding system of substation should be such that it should limit the potential gradients with in and around substation during normal and fault condition. Ground Fault creates potential rise within and around the substation which increases the step and touch potential. These potentials should be less than the permissible human body limit. For examination grounding grid of substation needs to calculate parameters related to earth and grounding for safe operation. In this paper parameters of existing design of grounding grid of substation are calculated with IEEE standard 80-2013 and some techniques are discussed for increasing grounding system safety. ETAP (Electrical power system analysis) software is used for analysis.

Key concepts: Ground, Earthing system, Limit (mathematics), Electric power system, Grid, Fault (geology), Reliability engineering, Power grid

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of grounding grid of substation — Research Paper | ScholarLens