Analysis of grounding grid of substation
Chetan S. Payshetti, Himmat Tukaram Jadhav, Shrihari Kulkarani
Abstract
Chetan S. Payshetti, Himmat Tukaram Jadhav, Shrihari Kulkarani
Abstract
The grounding system requires for maintaining safety of operators and apparatus and ensuring reliable working of power network. A grounding of substation connects electrical apparatus and the metallic structures to the common ground. Grounding system of substation should be such that it should limit the potential gradients with in and around substation during normal and fault condition. Ground Fault creates potential rise within and around the substation which increases the step and touch potential. These potentials should be less than the permissible human body limit. For examination grounding grid of substation needs to calculate parameters related to earth and grounding for safe operation. In this paper parameters of existing design of grounding grid of substation are calculated with IEEE standard 80-2013 and some techniques are discussed for increasing grounding system safety. ETAP (Electrical power system analysis) software is used for analysis.
OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The grounding system requires for maintaining safety of operators and apparatus and ensuring reliable working of power network. A grounding of substation connects electrical apparatus and the metallic structures to the common ground. Grounding system of substation should be such that it should limit the potential gradients with in and around substation during normal and fault condition. Ground Fault creates potential rise within and around the substation which increases the step and touch potential. These potentials should be less than the permissible human body limit. For examination grounding grid of substation needs to calculate parameters related to earth and grounding for safe operation. In this paper parameters of existing design of grounding grid of substation are calculated with IEEE standard 80-2013 and some techniques are discussed for increasing grounding system safety. ETAP (Electrical power system analysis) software is used for analysis.
Key concepts: Ground, Earthing system, Limit (mathematics), Electric power system, Grid, Fault (geology), Reliability engineering, Power grid