Determination of absorbed dose to water from a miniature kilovoltage x-ray source using a parallel-plate ionization chamber
Peter Watson, Marija Popović, Jan Seuntjens
Abstract
Peter Watson, Marija Popović, Jan Seuntjens
Abstract
Electronic brachytherapy sources are widely accepted as alternatives to radionuclide-based systems. Yet, formal dosimetry standards for these devices to independently complement the dose protocol provided by the manufacturer are lacking. This article presents a formalism for calculating and independently verifying the absorbed dose to water from a kV x-ray source (The INTRABEAM System) measured in a water phantom with an ionization chamber calibrated in terms of air-kerma. This formalism uses a Monte Carlo (MC) calculated chamber conversion factor, [Formula: see text], to convert air-kerma in a reference beam to absorbed dose to water in the measurement beam. In this work [Formula: see text] was determined for a PTW 34013 parallel-plate ionization chamber. Our results show that [Formula: see text] was sensitive to the chamber plate separation tolerance, with differences of up to 15%. [Formula: see text] was also found to have a depth dependence which varied with chamber plate separation (0 to 10% variation for the smallest and largest cavity height, over 3 to 30 mm depth). However for all chamber dimensions investigated, [Formula: see text] was found to be significantly larger than the manufacturer reported value, suggesting that the manufacturer recommended method of dose calculation could be underestimating the dose to water.
OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Electronic brachytherapy sources are widely accepted as alternatives to radionuclide-based systems. Yet, formal dosimetry standards for these devices to independently complement the dose protocol provided by the manufacturer are lacking. This article presents a formalism for calculating and independently verifying the absorbed dose to water from a kV x-ray source (The INTRABEAM System) measured in a water phantom with an ionization chamber calibrated in terms of air-kerma. This formalism uses a Monte Carlo (MC) calculated chamber conversion factor, [Formula: see text], to convert air-kerma in a reference beam to absorbed dose to water in the measurement beam. In this work [Formula: see text] was determined for a PTW 34013 parallel-plate ionization chamber. Our results show that [Formula: see text] was sensitive to the chamber plate separation tolerance, with differences of up to 15%. [Formula: see text] was also found to have a depth dependence which varied with chamber plate separation (0 to 10% variation for the smallest and largest cavity height, over 3 to 30 mm depth). However for all chamber dimensions investigated, [Formula: see text] was found to be significantly larger than the manufacturer reported value, suggesting that the manufacturer recommended method of dose calculation could be underestimating the dose to water.
Key concepts: Ionization chamber, Kerma, Absorbed dose, Dosimetry, Imaging phantom, Ionization, Monte Carlo method, Brachytherapy