Test and evaluation of a solar-powered laboratory turbocompressor system for building heating and cooling. Final technical report. [Rankine cycle]

F.R. Biancardi, G. Melikian, Abraham Landerman, J. B. Hall

Open full text 0 citations

Abstract

Extensive testing of an available laboratory Rankine-cycle turbocompressor cooling system was conducted over a range of temperatures consistent with present-day flat-plate and advanced medium-concentration solar collectors and at air- and water-cooled condenser temperature levels. Over 700 hours of testing demonstrated the high performance potential of such systems over a wide range of operational conditions and has provided design guidelines and preliminary specifications for future systems. Minor modifications were made to the laboratory system. These modifications included: (1) demonstration of three tons of cooling at a turbine inlet temperature of about 160 F, (2) efficient operation (i.e., COP of approximately 0.45) at turbine inlet temperatures of 240 F at air-cooled condenser temperatures, and (3) a COP in excess of 0.5 and more than five tons of cooling at system turbine inlet temperature levels of 200 F with water-cooled condenser temperatures. Generally, the test data correlated very well with detailed analytical design and off-design performance projections over the range of operating conditions. These data correlations indicate that the achieved performance levels were limited by mismatching of the existing turbomachinery elements. Data and experience obtained in this program substantiate the judgment that incorporating well-matched turbomachinery, based on existing technology, would result in the achievement of the full potential of a turbocompressor system for both air- and water-cooled operation. Prototype turbocompressor systems can be designed and developed which demonstrate high performance, (i.e., a COP approaching 1.0 and 0.75 for water and air-cooled operation, respectively), versatile operational features, permitting use of different collectors with a range of temperature capability, and potential for significant energy savings when used as solar-powered heating and cooling systems.

About this research paper

What this paper is about

Extensive testing of an available laboratory Rankine-cycle turbocompressor cooling system was conducted over a range of temperatures consistent with present-day flat-plate and advanced medium-concentration solar collectors and at air- and water-cooled condenser temperature levels. Over 700 hours of testing demonstrated the high performance potential of such systems over a wide range of operational conditions and has provided design guidelines and preliminary specifications for future systems. Minor modifications were made to the laboratory system. These modifications included: (1) demonstration of three tons of cooling at a turbine inlet temperature of about 160 F, (2) efficient operation (i.e., COP of approximately 0.45) at turbine inlet temperatures of 240 F at air-cooled condenser temperatures, and (3) a COP in excess of 0.5 and more than five tons of cooling at system turbine inlet temperature levels of 200 F with water-cooled condenser temperatures. Generally, the test data correlated very well with detailed analytical design and off-design performance projections over the range of operating conditions. These data correlations indicate that the achieved performance levels were limited by mismatching of the existing turbomachinery elements. Data and experience obtained in this program substantiate the judgment that incorporating well-matched turbomachinery, based on existing technology, would result in the achievement of the full potential of a turbocompressor system for both air- and water-cooled operation. Prototype turbocompressor systems can be designed and developed which demonstrate high performance, (i.e., a COP approaching 1.0 and 0.75 for water and air-cooled operation, respectively), versatile operational features, permitting use of different collectors with a range of temperature capability, and potential for significant energy savings when used as solar-powered heating and cooling systems.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Extensive testing of an available laboratory Rankine-cycle turbocompressor cooling system was conducted over a range of temperatures consistent with present-day flat-plate and advanced medium-concentration solar collectors and at air- and water-cooled condenser temperature levels. Over 700 hours of testing demonstrated the high performance potential of such systems over a wide range of operational conditions and has provided design guidelines and preliminary specifications for future systems. Minor modifications were made to the laboratory system. These modifications included: (1) demonstration of three tons of cooling at a turbine inlet temperature of about 160 F, (2) efficient operation (i.e., COP of approximately 0.45) at turbine inlet temperatures of 240 F at air-cooled condenser temperatures, and (3) a COP in excess of 0.5 and more than five tons of cooling at system turbine inlet temperature levels of 200 F with water-cooled condenser temperatures. Generally, the test data correlated very well with detailed analytical design and off-design performance projections over the range of operating conditions. These data correlations indicate that the achieved performance levels were limited by mismatching of the existing turbomachinery elements. Data and experience obtained in this program substantiate the judgment that incorporating well-matched turbomachinery, based on existing technology, would result in the achievement of the full potential of a turbocompressor system for both air- and water-cooled operation. Prototype turbocompressor systems can be designed and developed which demonstrate high performance, (i.e., a COP approaching 1.0 and 0.75 for water and air-cooled operation, respectively), versatile operational features, permitting use of different collectors with a range of temperature capability, and potential for significant energy savings when used as solar-powered heating and cooling systems.

Key concepts: Condenser (optics), Degree Rankine, Turbomachinery, Rankine cycle, Water cooling, Turbine, Environmental science, Nuclear engineering