ENERGY EFFICIENT PIPE HEAT EXCHANGER FOR WASTE HEAT RECOVERY FROM EXHAUST FLUE GASES
Andrei Burlacu, Constantin Doru Lăzărescu, Adrian Alexandru Şerbănoiu, Marinela Bărbuță, Vasilică Ciocan, Marina Verdeș
Abstract
Andrei Burlacu, Constantin Doru Lăzărescu, Adrian Alexandru Şerbănoiu, Marinela Bărbuță, Vasilică Ciocan, Marina Verdeș
Abstract
This study presents an original method for waste heat recovery from exhaust flue gases using a heat pipe heat exchanger.For the proposed paper we analyzed using Autodesk Simulation CFD Software the operation of the originally designed heat pipe heat exchanger system in different hypothesis.For the complete analysis we realized a study case for a pizza restaurant building located in Iasi, Romania to prove the energy efficiency of the heat pipe heat exchanger unit.By applying our system, we achieved a percent of energy savings of 30.9% for the total heat requirement for heating and domestic hot water preparation.In the end we realized a financial study using the RETScreen 4 Software to demonstrate the feasibility of using the heat pipe heat exchanger for waste heat recovery from exhaust flue gasses.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This study presents an original method for waste heat recovery from exhaust flue gases using a heat pipe heat exchanger.For the proposed paper we analyzed using Autodesk Simulation CFD Software the operation of the originally designed heat pipe heat exchanger system in different hypothesis.For the complete analysis we realized a study case for a pizza restaurant building located in Iasi, Romania to prove the energy efficiency of the heat pipe heat exchanger unit.By applying our system, we achieved a percent of energy savings of 30.9% for the total heat requirement for heating and domestic hot water preparation.In the end we realized a financial study using the RETScreen 4 Software to demonstrate the feasibility of using the heat pipe heat exchanger for waste heat recovery from exhaust flue gasses.
Key concepts: Recuperator, Waste heat recovery unit, Waste management, Waste heat, Heat exchanger, Flue gas, Heat recovery ventilation, Environmental science