2017Circulation JournalOpen access

Aneurysm Wall Enhancement Detected by Contrast Computed Tomography Scan Is Associated With Aneurysm Shrinkage After Endovascular Aneurysm Repair for Abdominal Aortic Aneurysm

Eisaku Ito, Naoki Toya, Soichiro Fukushima, Yuri Murakami, Tadashi Akiba, Takao Ohki

Open full text 14 citations

Abstract

BACKGROUND: Aneurysm expansion, and consequent endoleaks, after endovascular aneurysm repair (EVAR) is a major problem. Accurate prediction of aneurysm expansion is demanding for surgeons and remains difficult. METHODS AND RESULTS: We retrospectively analyzed 157 cases of EVAR for abdominal aortic aneurysm (AAA) using a bifurcated main-body stent-graft. There were 62 cases of aneurysm shrinkage after EVAR, 63 cases of stable aneurysm, and 32 cases of aneurysm expansion. Type I endoleaks were significantly increased in the aneurysm expansion group (EXP) compared with the stable (STB) and shrinkage (SHR) groups (EXP: 15.6% vs. STB: 4.8% vs. SHR: 0%, P=0.005). Type II endoleaks were also significantly increased in EXP (EXP: 65.6% vs. STB: 36.5% vs. SHR: 6.5%, P<0.001). Aneurysm wall enhancement (AWE) on imaging, however, was significantly decreased in the EXP group (EXP: 18.8% vs. STB: 23.8% vs. SHR: 53.2%, P<0.001). In multivariate analysis, the occurrence of type II endoleaks significantly decreased (P<0.001) and that of AWE significantly increased the likelihood of aneurysm shrinkage (P=0.032). CONCLUSIONS: AWE following EVAR may be associated with aneurysm shrinkage.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Aneurysm expansion, and consequent endoleaks, after endovascular aneurysm repair (EVAR) is a major problem. Accurate prediction of aneurysm expansion is demanding for surgeons and remains difficult. METHODS AND RESULTS: We retrospectively analyzed 157 cases of EVAR for abdominal aortic aneurysm (AAA) using a bifurcated main-body stent-graft. There were 62 cases of aneurysm shrinkage after EVAR, 63 cases of stable aneurysm, and 32 cases of aneurysm expansion. Type I endoleaks were significantly increased in the aneurysm expansion group (EXP) compared with the stable (STB) and shrinkage (SHR) groups (EXP: 15.6% vs. STB: 4.8% vs. SHR: 0%, P=0.005). Type II endoleaks were also significantly increased in EXP (EXP: 65.6% vs. STB: 36.5% vs. SHR: 6.5%, P<0.001). Aneurysm wall enhancement (AWE) on imaging, however, was significantly decreased in the EXP group (EXP: 18.8% vs. STB: 23.8% vs. SHR: 53.2%, P<0.001). In multivariate analysis, the occurrence of type II endoleaks significantly decreased (P<0.001) and that of AWE significantly increased the likelihood of aneurysm shrinkage (P=0.032). CONCLUSIONS: AWE following EVAR may be associated with aneurysm shrinkage.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Aneurysm expansion, and consequent endoleaks, after endovascular aneurysm repair (EVAR) is a major problem. Accurate prediction of aneurysm expansion is demanding for surgeons and remains difficult. METHODS AND RESULTS: We retrospectively analyzed 157 cases of EVAR for abdominal aortic aneurysm (AAA) using a bifurcated main-body stent-graft. There were 62 cases of aneurysm shrinkage after EVAR, 63 cases of stable aneurysm, and 32 cases of aneurysm expansion. Type I endoleaks were significantly increased in the aneurysm expansion group (EXP) compared with the stable (STB) and shrinkage (SHR) groups (EXP: 15.6% vs. STB: 4.8% vs. SHR: 0%, P=0.005). Type II endoleaks were also significantly increased in EXP (EXP: 65.6% vs. STB: 36.5% vs. SHR: 6.5%, P<0.001). Aneurysm wall enhancement (AWE) on imaging, however, was significantly decreased in the EXP group (EXP: 18.8% vs. STB: 23.8% vs. SHR: 53.2%, P<0.001). In multivariate analysis, the occurrence of type II endoleaks significantly decreased (P<0.001) and that of AWE significantly increased the likelihood of aneurysm shrinkage (P=0.032). CONCLUSIONS: AWE following EVAR may be associated with aneurysm shrinkage.

Key concepts: Aneurysm, Abdominal aortic aneurysm, Endovascular aneurysm repair, Medicine, Radiology, Computed tomography, Aortic aneurysm, Shrinkage

Related papers

Back to paper searchBrowse research topicsOriginal source
Aneurysm Wall Enhancement Detected by Contrast Computed Tomography Scan Is Associated With Aneurysm Shrinkage After Endovascular Aneurysm Repair for Abdominal Aortic Aneurysm — Research Paper | ScholarLens