An evaluation on the effect of night ventilation on thermal mass to reduce overheating in future climate scenarios
Carlos Jimenez-Bescos
Abstract
Carlos Jimenez-Bescos
Abstract
The aim of this study was to evaluate the influence of night ventilation on thermal mass benefits, with a view to alleviating the impact of future climate scenarios in terms of overheating. \nDynamic thermal simulations were used to analyse the overheating performance of a test room with exposed thermal mass. A range of night ventilation rates were simulated to evaluate their effect on thermal mass behaviour with regard to overheating according to different future climate and emission scenarios for London Islington. \nThe study shows that night ventilation rates of at least 8 acph are needed to provide significant overheating reductions. In the long term, ventilation rates under 10 acph will have little effect, allowing overheating reductions of less than 3% for high emissions scenarios and less than 8% for medium emissions scenarios. Different strategies must be in place if overheating is to be avoided due to warmer outdoor temperatures.
OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The aim of this study was to evaluate the influence of night ventilation on thermal mass benefits, with a view to alleviating the impact of future climate scenarios in terms of overheating. \nDynamic thermal simulations were used to analyse the overheating performance of a test room with exposed thermal mass. A range of night ventilation rates were simulated to evaluate their effect on thermal mass behaviour with regard to overheating according to different future climate and emission scenarios for London Islington. \nThe study shows that night ventilation rates of at least 8 acph are needed to provide significant overheating reductions. In the long term, ventilation rates under 10 acph will have little effect, allowing overheating reductions of less than 3% for high emissions scenarios and less than 8% for medium emissions scenarios. Different strategies must be in place if overheating is to be avoided due to warmer outdoor temperatures.
Key concepts: Overheating (electricity), Thermal mass, Environmental science, Thermal, Thermal comfort, Meteorology, Atmospheric sciences, Engineering