2017Journal of Oral RehabilitationRequires access

The effect of bolus volume on laryngeal closure and UES opening in swallowing: Kinematic analysis using 320‐row area detector CT study

Seiko Shibata, Yoko Inamoto, Eiichi Saitoh, Hitoshi Kagaya, Yoichiro Aoyagi, Kikuo Ota, Ryoko Akahori, Nobutaka Fujii, Jeffrey B. Palmer, Marlís González‐Fernández

Open publisher page 22 citations

Abstract

This study investigated the effects of three different volumes of honey-thick liquid on the temporal characteristics of swallowing. Twenty-six healthy subjects (15 males, 11 females) underwent 320-row area detector CT scan while swallowing 3, 10 and 20 mL of honey-thick liquid barium. Three-dimensional images were created at 10 images/s. Kinematic events involving six structures (velopharynx, hyoid bone, epiglottis, laryngeal vestibule (LV), true vocal cords (TVC), upper esophageal sphincter (UES)) and timing of bolus movement were timed using frame by frame analysis. The overall sequence of events did not differ across three volumes; however, increasing bolus volume significantly changed the onset and termination of events. The bolus head reached to pharynx and esophagus earlier and the duration of bolus passing through UES was significantly longer in 10 and 20 mL compared to 3 mL (P < .05). Consequently, the onset of UES opening was significantly earlier with increased volume (P < .05). LV and TVC closure occurred later in 20 mL compared to 3 mL (P < .05). These changes in motion of pharynx and larynx appeared to promote swallow safety by preventing aspiration, suggesting that anatomical structure movements adapt in response to bolus volume. Our findings also suggest that the pharyngeal swallow behaviours may be modified by afferents in the oral cavity. The three-dimensional visualization and quantitative measurements provided by 320-ADCT provide essential benchmarks for understanding swallowing, both normal and abnormal.

About this research paper

What this paper is about

This study investigated the effects of three different volumes of honey-thick liquid on the temporal characteristics of swallowing. Twenty-six healthy subjects (15 males, 11 females) underwent 320-row area detector CT scan while swallowing 3, 10 and 20 mL of honey-thick liquid barium. Three-dimensional images were created at 10 images/s. Kinematic events involving six structures (velopharynx, hyoid bone, epiglottis, laryngeal vestibule (LV), true vocal cords (TVC), upper esophageal sphincter (UES)) and timing of bolus movement were timed using frame by frame analysis. The overall sequence of events did not differ across three volumes; however, increasing bolus volume significantly changed the onset and termination of events. The bolus head reached to pharynx and esophagus earlier and the duration of bolus passing through UES was significantly longer in 10 and 20 mL compared to 3 mL (P < .05). Consequently, the onset of UES opening was significantly earlier with increased volume (P < .05). LV and TVC closure occurred later in 20 mL compared to 3 mL (P < .05). These changes in motion of pharynx and larynx appeared to promote swallow safety by preventing aspiration, suggesting that anatomical structure movements adapt in response to bolus volume. Our findings also suggest that the pharyngeal swallow behaviours may be modified by afferents in the oral cavity. The three-dimensional visualization and quantitative measurements provided by 320-ADCT provide essential benchmarks for understanding swallowing, both normal and abnormal.

Why it matters

OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study investigated the effects of three different volumes of honey-thick liquid on the temporal characteristics of swallowing. Twenty-six healthy subjects (15 males, 11 females) underwent 320-row area detector CT scan while swallowing 3, 10 and 20 mL of honey-thick liquid barium. Three-dimensional images were created at 10 images/s. Kinematic events involving six structures (velopharynx, hyoid bone, epiglottis, laryngeal vestibule (LV), true vocal cords (TVC), upper esophageal sphincter (UES)) and timing of bolus movement were timed using frame by frame analysis. The overall sequence of events did not differ across three volumes; however, increasing bolus volume significantly changed the onset and termination of events. The bolus head reached to pharynx and esophagus earlier and the duration of bolus passing through UES was significantly longer in 10 and 20 mL compared to 3 mL (P < .05). Consequently, the onset of UES opening was significantly earlier with increased volume (P < .05). LV and TVC closure occurred later in 20 mL compared to 3 mL (P < .05). These changes in motion of pharynx and larynx appeared to promote swallow safety by preventing aspiration, suggesting that anatomical structure movements adapt in response to bolus volume. Our findings also suggest that the pharyngeal swallow behaviours may be modified by afferents in the oral cavity. The three-dimensional visualization and quantitative measurements provided by 320-ADCT provide essential benchmarks for understanding swallowing, both normal and abnormal.

Key concepts: Swallowing, Epiglottis, Bolus (digestion), Pharynx, Medicine, Larynx, Nuclear medicine, Anatomy

Related papers

Back to paper searchBrowse research topicsOriginal source
The effect of bolus volume on laryngeal closure and UES opening in swallowing: Kinematic analysis using 320‐row area detector CT study — Research Paper | ScholarLens