2010Unpublished venueRequires access

GC/FID/액상주입 system의 장치간 VOCs 검출한계 비교

심녕주, 김수미, 김선태

Open publisher page 0 citations

Abstract

According to the development of GC equipment, it has been possible to analyze the low level of ambient VOCs concentration. In this study, the limit of detection and the limit of quantitation were estimated for two GC equipments of the VOCs analysis, which would contribute to improve the quality of VOCs analysis results. The results of %RSD for ten standard solutes showed a great reproducibility in terms of detection time and detection area. The limit of detection and the limit of quantitation in SRI GC appeared to be 0.175 ppb and 0.583 ppb for benzene, and 0.223 ppb and 0.743 ppb for toluene, respectively. On the other hand, The limit of detection and the limit of quantitation in FISON GC appeared to be 0.149 ppb and 0.496 ppb for benzene, and 0.094 ppb and 0.313 ppb for toluene, respectively.

About this research paper

What this paper is about

According to the development of GC equipment, it has been possible to analyze the low level of ambient VOCs concentration. In this study, the limit of detection and the limit of quantitation were estimated for two GC equipments of the VOCs analysis, which would contribute to improve the quality of VOCs analysis results. The results of %RSD for ten standard solutes showed a great reproducibility in terms of detection time and detection area. The limit of detection and the limit of quantitation in SRI GC appeared to be 0.175 ppb and 0.583 ppb for benzene, and 0.223 ppb and 0.743 ppb for toluene, respectively. On the other hand, The limit of detection and the limit of quantitation in FISON GC appeared to be 0.149 ppb and 0.496 ppb for benzene, and 0.094 ppb and 0.313 ppb for toluene, respectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

According to the development of GC equipment, it has been possible to analyze the low level of ambient VOCs concentration. In this study, the limit of detection and the limit of quantitation were estimated for two GC equipments of the VOCs analysis, which would contribute to improve the quality of VOCs analysis results. The results of %RSD for ten standard solutes showed a great reproducibility in terms of detection time and detection area. The limit of detection and the limit of quantitation in SRI GC appeared to be 0.175 ppb and 0.583 ppb for benzene, and 0.223 ppb and 0.743 ppb for toluene, respectively. On the other hand, The limit of detection and the limit of quantitation in FISON GC appeared to be 0.149 ppb and 0.496 ppb for benzene, and 0.094 ppb and 0.313 ppb for toluene, respectively.

Key concepts: Detection limit, Benzene, Toluene, Reproducibility, Chromatography, Chemistry, Gas chromatography, Environmental chemistry

Back to paper searchBrowse research topicsOriginal source
GC/FID/액상주입 system의 장치간 VOCs 검출한계 비교 — Research Paper | ScholarLens