2017Janaki Medical College Journal of Medical ScienceOpen access

Application of Cone-Beam Computed Tomography (CBCT) in diagnosis and evaluation of Supernumerary Teeth

Rishikesh Pratap Sah, Fusheng Dong, Rahul Gupta

Open full text 1 citations

Abstract

Background and Objectives: The aim of this paper is to describe the application of a newly developed three-dimensional imaging system, Cone-Beam Computed Tomography in the diagnosis and evaluation of supernumerary teeth.Material and Methods: One hundred and eighty-five patients with supernumerary teeth (134 males and 51 females) were included in this study. Patients ranged in age from 6 to 38 years. Supernumerary teeth were detected by clinical examination and conventional radiographs. Moreover, careful investigation for more details was made with the cone beam computed tomography. Supernumerary teeth which were detected with the examinations of the cone beam computed tomography images were analyzed according to the number, location, shape and position.Results: Males were affected more than females in a ratio of 2.6:1. 95 % supernumerary teeth were located in maxilla and 5 % in the mandible. 71.6% of supernumerary teeth were conical in shape. 93.6% supernumerary teeth were impacted and 6.4% were erupted. A total of 198 supernumerary teeth were found to be present in palatal/lingual side and 24 were found on the buccal side. 80.5 % of the patients had one, 18.9 % had two, and 0.5 % had three supernumeraries.Conclusion: Detailed examinations and evaluations of these teeth with Cone-Beam Computed tomography (CBCT) yields accurate 3-dimensional pictures of supernumerary teeth, local dental and bony structures which are very beneficial in terms of proper diagnosis and treatment planning and preventing complications which may occur. Janaki Medical College Journal of Medical Sciences (2017) Vol. 5(1): 5-15

Open-access reader

About this research paper

What this paper is about

Background and Objectives: The aim of this paper is to describe the application of a newly developed three-dimensional imaging system, Cone-Beam Computed Tomography in the diagnosis and evaluation of supernumerary teeth.Material and Methods: One hundred and eighty-five patients with supernumerary teeth (134 males and 51 females) were included in this study. Patients ranged in age from 6 to 38 years. Supernumerary teeth were detected by clinical examination and conventional radiographs. Moreover, careful investigation for more details was made with the cone beam computed tomography. Supernumerary teeth which were detected with the examinations of the cone beam computed tomography images were analyzed according to the number, location, shape and position.Results: Males were affected more than females in a ratio of 2.6:1. 95 % supernumerary teeth were located in maxilla and 5 % in the mandible. 71.6% of supernumerary teeth were conical in shape. 93.6% supernumerary teeth were impacted and 6.4% were erupted. A total of 198 supernumerary teeth were found to be present in palatal/lingual side and 24 were found on the buccal side. 80.5 % of the patients had one, 18.9 % had two, and 0.5 % had three supernumeraries.Conclusion: Detailed examinations and evaluations of these teeth with Cone-Beam Computed tomography (CBCT) yields accurate 3-dimensional pictures of supernumerary teeth, local dental and bony structures which are very beneficial in terms of proper diagnosis and treatment planning and preventing complications which may occur. Janaki Medical College Journal of Medical Sciences (2017) Vol. 5(1): 5-15

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background and Objectives: The aim of this paper is to describe the application of a newly developed three-dimensional imaging system, Cone-Beam Computed Tomography in the diagnosis and evaluation of supernumerary teeth.Material and Methods: One hundred and eighty-five patients with supernumerary teeth (134 males and 51 females) were included in this study. Patients ranged in age from 6 to 38 years. Supernumerary teeth were detected by clinical examination and conventional radiographs. Moreover, careful investigation for more details was made with the cone beam computed tomography. Supernumerary teeth which were detected with the examinations of the cone beam computed tomography images were analyzed according to the number, location, shape and position.Results: Males were affected more than females in a ratio of 2.6:1. 95 % supernumerary teeth were located in maxilla and 5 % in the mandible. 71.6% of supernumerary teeth were conical in shape. 93.6% supernumerary teeth were impacted and 6.4% were erupted. A total of 198 supernumerary teeth were found to be present in palatal/lingual side and 24 were found on the buccal side. 80.5 % of the patients had one, 18.9 % had two, and 0.5 % had three supernumeraries.Conclusion: Detailed examinations and evaluations of these teeth with Cone-Beam Computed tomography (CBCT) yields accurate 3-dimensional pictures of supernumerary teeth, local dental and bony structures which are very beneficial in terms of proper diagnosis and treatment planning and preventing complications which may occur. Janaki Medical College Journal of Medical Sciences (2017) Vol. 5(1): 5-15

Key concepts: Supernumerary, Cone beam computed tomography, Medicine, Maxilla, Supernumerary tooth, Radiography, Dentistry, Orthodontics

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of Cone-Beam Computed Tomography (CBCT) in diagnosis and evaluation of Supernumerary Teeth — Research Paper | ScholarLens