Two-phase liquid cooling system for electronics, part 2: Air-cooled condenser
Raffaele L. Amalfi, Todd Salamon, Nicolas Lamaison, Jackson B. Marcinichen, John R. Thome
Abstract
Raffaele L. Amalfi, Todd Salamon, Nicolas Lamaison, Jackson B. Marcinichen, John R. Thome
Abstract
An experimental study investigating the thermal performance of a two-phase thermosyphon for electronics cooling is presented in this article. Two-phase cooling implemented using a gravity-driven thermosyphon-based system represents an efficient solution for dissipating high power densities compared to traditional air-cooling approaches, allowing for increased reliability and reduced power consumption. The thermosyphon-based system consists of an evaporator with 18 individual microcooling zones connected via riser and downcomer tubes to an air-cooled condenser. Experiments were carried out with working fluid R134a for filling ratios ranging from 45% to 65%, heat loads from 102 W to 1841 W and air flow rates from 516 m3/h to 1404 m3/h. Robust thermal performance was observed for the entire range of operating conditions. In particular, at the optimum filling ratio of 50%, minimum air flow rate of 516 m3/h and uniform heat load of 1841 W, the temperature difference between the evaporator and ambient air was less than 20 K with a COP of 102, while at the highest fan speed of 1404 m3/h this temperature difference was reduced to 8.9 K, with a reasonable COP of 11. The test results show the high efficiency of the current hybrid air- and liquid-based cooling technology for removing heat from electronics to the ambient.
OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
An experimental study investigating the thermal performance of a two-phase thermosyphon for electronics cooling is presented in this article. Two-phase cooling implemented using a gravity-driven thermosyphon-based system represents an efficient solution for dissipating high power densities compared to traditional air-cooling approaches, allowing for increased reliability and reduced power consumption. The thermosyphon-based system consists of an evaporator with 18 individual microcooling zones connected via riser and downcomer tubes to an air-cooled condenser. Experiments were carried out with working fluid R134a for filling ratios ranging from 45% to 65%, heat loads from 102 W to 1841 W and air flow rates from 516 m3/h to 1404 m3/h. Robust thermal performance was observed for the entire range of operating conditions. In particular, at the optimum filling ratio of 50%, minimum air flow rate of 516 m3/h and uniform heat load of 1841 W, the temperature difference between the evaporator and ambient air was less than 20 K with a COP of 102, while at the highest fan speed of 1404 m3/h this temperature difference was reduced to 8.9 K, with a reasonable COP of 11. The test results show the high efficiency of the current hybrid air- and liquid-based cooling technology for removing heat from electronics to the ambient.
Key concepts: Condenser (optics), Evaporator, Thermosiphon, Computer cooling, Thermodynamics, Airflow, Heat pipe, Volumetric flow rate