2017The Journal of Strength and Conditioning ResearchOpen access

Assessment of Loaded Squat Jump Height With a Free-Weight Barbell and Smith Machine: Comparison of the Takeoff Velocity and Flight Time Procedures

Alejandro Pérez‐Castilla, John J. McMahon, Paul Comfort, Amador García‐Ramos

Open full text 44 citations

Abstract

Pérez-Castilla, A, McMahon, JJ, Comfort, P, and García-Ramos, A. Assessment of loaded squat jump height with a free-weight barbell and Smith machine: comparison of the takeoff velocity and flight time procedures. J Strength Cond Res 34(3): 671-677, 2020-The aims of this study were to compare the reliability and magnitude of jump height between the 2 standard procedures of analyzing force platform data to estimate jump height (takeoff velocity [TOV] and flight time [FT]) in the loaded squat jump (SJ) exercise performed with a free-weight barbell and in a Smith machine. Twenty-three collegiate men (age, 23.1 ± 3.2 years; body mass, 74.7 ± 7.3 kg; height, 177.1 ± 7.0 cm) were tested twice for each SJ type (free-weight barbell and Smith machine) with 17-, 30-, 45-, 60-, and 75-kg loads. No substantial differences in reliability were observed between the TOV (coefficient of variation [CV], 9.88%; intraclass correlation coefficient [ICC], 0.82) and FT (CV, 8.68%; ICC, 0.88) procedures (CV ratio, 1.14), whereas the Smith SJ (CV, 7.74%; ICC, 0.87) revealed a higher reliability than the free-weight SJ (CV, 9.88%; ICC, 0.81; CV ratio, 1.28). The TOV procedure provided higher magnitudes of jump height than the FT procedure for the loaded Smith machine SJ (systematic bias, 2.64 cm; p ≤ 0.05), whereas no significant differences between the TOV and FT procedures were observed in the free-weight SJ exercise (systematic bias, 0.26 cm; p > 0.05). Heteroscedasticity of the errors was observed for the Smith machine SJ (r = 0.177) with increasing differences in favor of the TOV procedure for the trials with lower jump height (i.e., higher external loads). Based on these results, the use of a Smith machine in conjunction with the FT more accurately determine jump height during the loaded SJ.

Open-access reader

About this research paper

What this paper is about

Pérez-Castilla, A, McMahon, JJ, Comfort, P, and García-Ramos, A. Assessment of loaded squat jump height with a free-weight barbell and Smith machine: comparison of the takeoff velocity and flight time procedures. J Strength Cond Res 34(3): 671-677, 2020-The aims of this study were to compare the reliability and magnitude of jump height between the 2 standard procedures of analyzing force platform data to estimate jump height (takeoff velocity [TOV] and flight time [FT]) in the loaded squat jump (SJ) exercise performed with a free-weight barbell and in a Smith machine. Twenty-three collegiate men (age, 23.1 ± 3.2 years; body mass, 74.7 ± 7.3 kg; height, 177.1 ± 7.0 cm) were tested twice for each SJ type (free-weight barbell and Smith machine) with 17-, 30-, 45-, 60-, and 75-kg loads. No substantial differences in reliability were observed between the TOV (coefficient of variation [CV], 9.88%; intraclass correlation coefficient [ICC], 0.82) and FT (CV, 8.68%; ICC, 0.88) procedures (CV ratio, 1.14), whereas the Smith SJ (CV, 7.74%; ICC, 0.87) revealed a higher reliability than the free-weight SJ (CV, 9.88%; ICC, 0.81; CV ratio, 1.28). The TOV procedure provided higher magnitudes of jump height than the FT procedure for the loaded Smith machine SJ (systematic bias, 2.64 cm; p ≤ 0.05), whereas no significant differences between the TOV and FT procedures were observed in the free-weight SJ exercise (systematic bias, 0.26 cm; p > 0.05). Heteroscedasticity of the errors was observed for the Smith machine SJ (r = 0.177) with increasing differences in favor of the TOV procedure for the trials with lower jump height (i.e., higher external loads). Based on these results, the use of a Smith machine in conjunction with the FT more accurately determine jump height during the loaded SJ.

Why it matters

OpenAlex reports 44 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Pérez-Castilla, A, McMahon, JJ, Comfort, P, and García-Ramos, A. Assessment of loaded squat jump height with a free-weight barbell and Smith machine: comparison of the takeoff velocity and flight time procedures. J Strength Cond Res 34(3): 671-677, 2020-The aims of this study were to compare the reliability and magnitude of jump height between the 2 standard procedures of analyzing force platform data to estimate jump height (takeoff velocity [TOV] and flight time [FT]) in the loaded squat jump (SJ) exercise performed with a free-weight barbell and in a Smith machine. Twenty-three collegiate men (age, 23.1 ± 3.2 years; body mass, 74.7 ± 7.3 kg; height, 177.1 ± 7.0 cm) were tested twice for each SJ type (free-weight barbell and Smith machine) with 17-, 30-, 45-, 60-, and 75-kg loads. No substantial differences in reliability were observed between the TOV (coefficient of variation [CV], 9.88%; intraclass correlation coefficient [ICC], 0.82) and FT (CV, 8.68%; ICC, 0.88) procedures (CV ratio, 1.14), whereas the Smith SJ (CV, 7.74%; ICC, 0.87) revealed a higher reliability than the free-weight SJ (CV, 9.88%; ICC, 0.81; CV ratio, 1.28). The TOV procedure provided higher magnitudes of jump height than the FT procedure for the loaded Smith machine SJ (systematic bias, 2.64 cm; p ≤ 0.05), whereas no significant differences between the TOV and FT procedures were observed in the free-weight SJ exercise (systematic bias, 0.26 cm; p > 0.05). Heteroscedasticity of the errors was observed for the Smith machine SJ (r = 0.177) with increasing differences in favor of the TOV procedure for the trials with lower jump height (i.e., higher external loads). Based on these results, the use of a Smith machine in conjunction with the FT more accurately determine jump height during the loaded SJ.

Key concepts: Takeoff, Squat, Jump, Mathematics, Coefficient of variation, Intraclass correlation, Body weight, Statistics

Related papers

Back to paper searchBrowse research topicsOriginal source
Assessment of Loaded Squat Jump Height With a Free-Weight Barbell and Smith Machine: Comparison of the Takeoff Velocity and Flight Time Procedures — Research Paper | ScholarLens