2017Circulation Cardiovascular InterventionsOpen access

Time-Course Reduction in Patient Exposure to Radiation From Coronary Interventional Procedures

Jean‐Louis Georges, Nicole Karam, Muriel Tafflet, B. Livarek, Sophie Bataille, Aurélie Loyeau, Mireille Mapouata, Hakim Benamer, Christophe Caussin, Philippe Garot, Olivier Varenne, Franck Barbou, Emmanuel Teíger, Francois Funck, Gaëtan J. Karrillon, Yves Lambert, Christian M. Spaulding, Xavier Jouven

Open full text 13 citations

Abstract

Background— The frequency of complex percutaneous coronary interventions (PCIs) has increased in the last few years, with a growing concern on the radiation dose received by the patients. Multicenter data from large unselected populations on patients’ radiation doses during coronary angiography (CA) and PCI and temporal trends are lacking. This study sought to evaluate the temporal trends in patients’ exposure to radiation from CA and PCI. Methods and Results— Data were taken from the CARDIO-ARSIF registry that prospectively collects data on all CAs and PCIs performed in the 36 catheterization laboratories in the Greater Paris Area, the most populated regions in France with about 12 million inhabitants. Kerma area product and Fluoroscopy time from 152 684 consecutive CAs and 103 177 PCIs performed between 2009 and 2013 were analyzed. A continuous trend for a decrease in median [interquartile range] Kerma area product was observed, from 33 [19–55] Gy cm 2 in 2009 to 27 [16–44] Gy cm 2 in 2013 for CA ( P <0.0001), and from 73 [41–125] to 55 [31–91] Gy cm 2 for PCI ( P <0.0001). Time-course differences in Kerma area product remained highly significant after adjustment on Fluoroscopy time, PCI procedure complexity, change of x-ray equipment, and other patient- and procedure-related covariates. Conclusions— In a large patient population, a steady temporal decrease in patient radiation exposure during CA and PCI was noted between 2009 and 2013. Kerma area product reduction was consistent in all types of procedure and was independent of patient-related factors and PCI procedure complexity.

Open-access reader

About this research paper

What this paper is about

Background— The frequency of complex percutaneous coronary interventions (PCIs) has increased in the last few years, with a growing concern on the radiation dose received by the patients. Multicenter data from large unselected populations on patients’ radiation doses during coronary angiography (CA) and PCI and temporal trends are lacking. This study sought to evaluate the temporal trends in patients’ exposure to radiation from CA and PCI. Methods and Results— Data were taken from the CARDIO-ARSIF registry that prospectively collects data on all CAs and PCIs performed in the 36 catheterization laboratories in the Greater Paris Area, the most populated regions in France with about 12 million inhabitants. Kerma area product and Fluoroscopy time from 152 684 consecutive CAs and 103 177 PCIs performed between 2009 and 2013 were analyzed. A continuous trend for a decrease in median [interquartile range] Kerma area product was observed, from 33 [19–55] Gy cm 2 in 2009 to 27 [16–44] Gy cm 2 in 2013 for CA ( P <0.0001), and from 73 [41–125] to 55 [31–91] Gy cm 2 for PCI ( P <0.0001). Time-course differences in Kerma area product remained highly significant after adjustment on Fluoroscopy time, PCI procedure complexity, change of x-ray equipment, and other patient- and procedure-related covariates. Conclusions— In a large patient population, a steady temporal decrease in patient radiation exposure during CA and PCI was noted between 2009 and 2013. Kerma area product reduction was consistent in all types of procedure and was independent of patient-related factors and PCI procedure complexity.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background— The frequency of complex percutaneous coronary interventions (PCIs) has increased in the last few years, with a growing concern on the radiation dose received by the patients. Multicenter data from large unselected populations on patients’ radiation doses during coronary angiography (CA) and PCI and temporal trends are lacking. This study sought to evaluate the temporal trends in patients’ exposure to radiation from CA and PCI. Methods and Results— Data were taken from the CARDIO-ARSIF registry that prospectively collects data on all CAs and PCIs performed in the 36 catheterization laboratories in the Greater Paris Area, the most populated regions in France with about 12 million inhabitants. Kerma area product and Fluoroscopy time from 152 684 consecutive CAs and 103 177 PCIs performed between 2009 and 2013 were analyzed. A continuous trend for a decrease in median [interquartile range] Kerma area product was observed, from 33 [19–55] Gy cm 2 in 2009 to 27 [16–44] Gy cm 2 in 2013 for CA ( P <0.0001), and from 73 [41–125] to 55 [31–91] Gy cm 2 for PCI ( P <0.0001). Time-course differences in Kerma area product remained highly significant after adjustment on Fluoroscopy time, PCI procedure complexity, change of x-ray equipment, and other patient- and procedure-related covariates. Conclusions— In a large patient population, a steady temporal decrease in patient radiation exposure during CA and PCI was noted between 2009 and 2013. Kerma area product reduction was consistent in all types of procedure and was independent of patient-related factors and PCI procedure complexity.

Key concepts: Medicine, Fluoroscopy, Conventional PCI, Kerma, Dose area product, Interquartile range, Nuclear medicine, Radiation exposure

Related papers

Back to paper searchBrowse research topicsOriginal source
Time-Course Reduction in Patient Exposure to Radiation From Coronary Interventional Procedures — Research Paper | ScholarLens