2010Proceedings of SimBuildRequires access

DEVELOPMENT OF A CALIBRATION METHODOLOGY FOR THE ENERGY SIMULATION OF AN EXISTING BUILDING FROM 1969

Tobias Leibing, Claudius Reiser, Oliver Baumann

Open publisher page 0 citations

Abstract

The increasing need for building renovation to meet new energy efficiency requirements is accompanied by a growing demand for whole building energy simulations. To have a simulation model that reflects the as-is conditions and is calibrated to measured energy consumption and performance is key to make a profound statement about the potentials of proposed energy conservation measures There are a lot of theoretical methodologies available for how to calibrate simulation models; however, they are often not suitable for a cost effective day-to-day practice. The scope of the case study presented in this paper is to develop a methodology for building calibration based on an existing hotel building with the following major topics: 1) Description of a practical methodology calibration 2) Challenges and pitfalls of the calibration of an existing building 3) Identification of the information required minimum project 4) Definition of the quality grade of the final simulation As part of the Net-Zero Energy Commercial Building Initiative (CBI) of the U.S. Department of Energy an existing hotel building from 1969 was outfitted with extensive monitoring equipment in conjunction with the Pacific Northwest National Laboratory (PNNL). Thus, detailed insight in the building operation could be used to calibrate the HVAC (heating, ventilation, air conditioning) systems as well as the occupancy. Based on this information, the influence and sensitivity of single systems as well as the building in its entirety could

About this research paper

What this paper is about

The increasing need for building renovation to meet new energy efficiency requirements is accompanied by a growing demand for whole building energy simulations. To have a simulation model that reflects the as-is conditions and is calibrated to measured energy consumption and performance is key to make a profound statement about the potentials of proposed energy conservation measures There are a lot of theoretical methodologies available for how to calibrate simulation models; however, they are often not suitable for a cost effective day-to-day practice. The scope of the case study presented in this paper is to develop a methodology for building calibration based on an existing hotel building with the following major topics: 1) Description of a practical methodology calibration 2) Challenges and pitfalls of the calibration of an existing building 3) Identification of the information required minimum project 4) Definition of the quality grade of the final simulation As part of the Net-Zero Energy Commercial Building Initiative (CBI) of the U.S. Department of Energy an existing hotel building from 1969 was outfitted with extensive monitoring equipment in conjunction with the Pacific Northwest National Laboratory (PNNL). Thus, detailed insight in the building operation could be used to calibrate the HVAC (heating, ventilation, air conditioning) systems as well as the occupancy. Based on this information, the influence and sensitivity of single systems as well as the building in its entirety could

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The increasing need for building renovation to meet new energy efficiency requirements is accompanied by a growing demand for whole building energy simulations. To have a simulation model that reflects the as-is conditions and is calibrated to measured energy consumption and performance is key to make a profound statement about the potentials of proposed energy conservation measures There are a lot of theoretical methodologies available for how to calibrate simulation models; however, they are often not suitable for a cost effective day-to-day practice. The scope of the case study presented in this paper is to develop a methodology for building calibration based on an existing hotel building with the following major topics: 1) Description of a practical methodology calibration 2) Challenges and pitfalls of the calibration of an existing building 3) Identification of the information required minimum project 4) Definition of the quality grade of the final simulation As part of the Net-Zero Energy Commercial Building Initiative (CBI) of the U.S. Department of Energy an existing hotel building from 1969 was outfitted with extensive monitoring equipment in conjunction with the Pacific Northwest National Laboratory (PNNL). Thus, detailed insight in the building operation could be used to calibrate the HVAC (heating, ventilation, air conditioning) systems as well as the occupancy. Based on this information, the influence and sensitivity of single systems as well as the building in its entirety could

Key concepts: HVAC, Building energy simulation, Calibration, Scope (computer science), Energy consumption, Computer science, Key (lock), Efficient energy use

Related papers

Back to paper searchBrowse research topicsOriginal source
DEVELOPMENT OF A CALIBRATION METHODOLOGY FOR THE ENERGY SIMULATION OF AN EXISTING BUILDING FROM 1969 — Research Paper | ScholarLens