Study on natural soil coagulants for point-of-use drinking water treatment
Xuejiao Qi, Hongtao Wang, Eyasu Tarekegn Getahun, Muxi Luo, Zuohong Chen, Haowen Duan, Tongxuan Ren, Yi‐nan Wu, Fengting Li
Abstract
Open-access reader
Xuejiao Qi, Hongtao Wang, Eyasu Tarekegn Getahun, Muxi Luo, Zuohong Chen, Haowen Duan, Tongxuan Ren, Yi‐nan Wu, Fengting Li
Abstract
Open-access reader
Natural soil coagulants were used for domestic drinking water treatment in Ethiopia because of lacking drinking water supply. In this study, two soils were collected from Ethiopia and jar test was used to investigate the optimum working conditions, performance and safety of them. The turbidity removal efficiencies of soil A and soil B are 74.5% and 91.1% (initial turbidity=400 NTU), respectively. The pH of purified water can meet drinking water standards of Ethiopia (pH=6.5-8.5). Both soils contribute to remove TOC when the initial concentration of it is high. A small amount (0.5 mg. L-1 or 1 mg. L-1) of poly-aluminum chloride can improve the performance of soil coagulants for the removal of turbidity. The application of soil coagulants didn't introduce coliforms, although the total bacteria number of treated water increased to 40 CFU (soil A) and 81 CFU (soil B), still meeting the drinking water quality standards (<=100 CFU).
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Natural soil coagulants were used for domestic drinking water treatment in Ethiopia because of lacking drinking water supply. In this study, two soils were collected from Ethiopia and jar test was used to investigate the optimum working conditions, performance and safety of them. The turbidity removal efficiencies of soil A and soil B are 74.5% and 91.1% (initial turbidity=400 NTU), respectively. The pH of purified water can meet drinking water standards of Ethiopia (pH=6.5-8.5). Both soils contribute to remove TOC when the initial concentration of it is high. A small amount (0.5 mg. L-1 or 1 mg. L-1) of poly-aluminum chloride can improve the performance of soil coagulants for the removal of turbidity. The application of soil coagulants didn't introduce coliforms, although the total bacteria number of treated water increased to 40 CFU (soil A) and 81 CFU (soil B), still meeting the drinking water quality standards (<=100 CFU).
Key concepts: Turbidity, Environmental science, Soil water, Environmental engineering, Water quality, Chloride, Water treatment, Environmental chemistry