2017•Journal of Surgical Case ReportsOpen access

Non-curative surgery for aortoenteric fistula

Bent‐Are Hansen, Svein Roar Amundsen, Håkon Reikvam, Øystein Wendelbo, Gustav Pedersen

Open full text 10 citations

Abstract

Graft infection with secondary aortic fistula is a rare complication following implantation of aortic prostheses, frequently occurring after emergency procedures and reoperations. The condition is associated with considerable morbidity and mortality. Curative treatment consists of explantation of the infected graft followed by fistula revision and implantation of a new graft in combination with antimicrobial therapy. Non-curative treatment with aortic stentgraft and long-term substitution treatment with antibiotics may be an option in cases where graft explantation is deemed too risky. We present an elderly patient with aortoenteric fistula following surgery for ruptured abdominal aortic aneurysm. Implantation of an aortic stentgraft and fistula revision was performed but the original aortic prosthesis was not explanted. The aortoenteric fistula recurred twice, but the patient has survived more than 12 years following non-curative surgery with good quality of life.

Open-access reader

About this research paper

What this paper is about

Graft infection with secondary aortic fistula is a rare complication following implantation of aortic prostheses, frequently occurring after emergency procedures and reoperations. The condition is associated with considerable morbidity and mortality. Curative treatment consists of explantation of the infected graft followed by fistula revision and implantation of a new graft in combination with antimicrobial therapy. Non-curative treatment with aortic stentgraft and long-term substitution treatment with antibiotics may be an option in cases where graft explantation is deemed too risky. We present an elderly patient with aortoenteric fistula following surgery for ruptured abdominal aortic aneurysm. Implantation of an aortic stentgraft and fistula revision was performed but the original aortic prosthesis was not explanted. The aortoenteric fistula recurred twice, but the patient has survived more than 12 years following non-curative surgery with good quality of life.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Graft infection with secondary aortic fistula is a rare complication following implantation of aortic prostheses, frequently occurring after emergency procedures and reoperations. The condition is associated with considerable morbidity and mortality. Curative treatment consists of explantation of the infected graft followed by fistula revision and implantation of a new graft in combination with antimicrobial therapy. Non-curative treatment with aortic stentgraft and long-term substitution treatment with antibiotics may be an option in cases where graft explantation is deemed too risky. We present an elderly patient with aortoenteric fistula following surgery for ruptured abdominal aortic aneurysm. Implantation of an aortic stentgraft and fistula revision was performed but the original aortic prosthesis was not explanted. The aortoenteric fistula recurred twice, but the patient has survived more than 12 years following non-curative surgery with good quality of life.

Key concepts: Medicine, Aortoenteric fistula, Surgery, Fistula, Aortic surgery, Complication, Prosthesis, Abdominal aortic aneurysm

Related papers

Back to paper searchBrowse research topicsOriginal source
Non-curative surgery for aortoenteric fistula — Research Paper | ScholarLens