2017•Electric Power Components and SystemsRequires access

Short Circuit Current Calculation Method of Doubly-Fed Induction Generator with Crowbar Protection Based on Flux Transient Characteristics

Jing Ma, Weibo Zhang, Yu Zhao, Yubo Song, James S. Thorp

Open publisher page 5 citations

Abstract

With the wide application of doubly-fed induction generator (DFIG), accurate calculation and analysis of the short circuit currents of DFIG with crowbar protection has become very important key to realizing the low voltage ride through (LVRT) capability of DFIG and establishing the corresponding grid protection scheme. In view of this, a method to calculate the short circuit currents of DFIG with crowbar protection when different types of fault occur in the grid is proposed in this paper. First, the DFIG stator and rotor 2nd-order differential equations in the cases of grid symmetrical fault and asymmetrical fault are established respectively. And the short circuit current calculation model when crowbar resistance remains unchanged in the fault duration is obtained. On this basis, the short circuit current calculation model when crowbar resistance varies in the fault duration is derived. And then, the influence of crowbar resistance and DFIG rotor speed on the short circuit current calculation model is analyzed, including the variation pattern of flux eigenvalues with the crowbar resistance, and the variation feature of flux amplitude and phase angle with the rotor speed. Besides, the transient variation characteristics of different flux components are studied. Finally, time-domain simulation tests verify that the proposed calculation method is correct and applicable to different types of crowbar circuits in the market. Besides, the influence of crowbar resistance and DFIG rotor speed on the stator short circuit current peak, peak time and current frequency in different fault cases is revealed.

About this research paper

What this paper is about

With the wide application of doubly-fed induction generator (DFIG), accurate calculation and analysis of the short circuit currents of DFIG with crowbar protection has become very important key to realizing the low voltage ride through (LVRT) capability of DFIG and establishing the corresponding grid protection scheme. In view of this, a method to calculate the short circuit currents of DFIG with crowbar protection when different types of fault occur in the grid is proposed in this paper. First, the DFIG stator and rotor 2nd-order differential equations in the cases of grid symmetrical fault and asymmetrical fault are established respectively. And the short circuit current calculation model when crowbar resistance remains unchanged in the fault duration is obtained. On this basis, the short circuit current calculation model when crowbar resistance varies in the fault duration is derived. And then, the influence of crowbar resistance and DFIG rotor speed on the short circuit current calculation model is analyzed, including the variation pattern of flux eigenvalues with the crowbar resistance, and the variation feature of flux amplitude and phase angle with the rotor speed. Besides, the transient variation characteristics of different flux components are studied. Finally, time-domain simulation tests verify that the proposed calculation method is correct and applicable to different types of crowbar circuits in the market. Besides, the influence of crowbar resistance and DFIG rotor speed on the stator short circuit current peak, peak time and current frequency in different fault cases is revealed.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

With the wide application of doubly-fed induction generator (DFIG), accurate calculation and analysis of the short circuit currents of DFIG with crowbar protection has become very important key to realizing the low voltage ride through (LVRT) capability of DFIG and establishing the corresponding grid protection scheme. In view of this, a method to calculate the short circuit currents of DFIG with crowbar protection when different types of fault occur in the grid is proposed in this paper. First, the DFIG stator and rotor 2nd-order differential equations in the cases of grid symmetrical fault and asymmetrical fault are established respectively. And the short circuit current calculation model when crowbar resistance remains unchanged in the fault duration is obtained. On this basis, the short circuit current calculation model when crowbar resistance varies in the fault duration is derived. And then, the influence of crowbar resistance and DFIG rotor speed on the short circuit current calculation model is analyzed, including the variation pattern of flux eigenvalues with the crowbar resistance, and the variation feature of flux amplitude and phase angle with the rotor speed. Besides, the transient variation characteristics of different flux components are studied. Finally, time-domain simulation tests verify that the proposed calculation method is correct and applicable to different types of crowbar circuits in the market. Besides, the influence of crowbar resistance and DFIG rotor speed on the stator short circuit current peak, peak time and current frequency in different fault cases is revealed.

Key concepts: Crowbar, Stator, Rotor (electric), Fault (geology), Transient (computer programming), Control theory (sociology), Induction generator, Short circuit

Related papers

Back to paper searchBrowse research topicsOriginal source
Short Circuit Current Calculation Method of Doubly-Fed Induction Generator with Crowbar Protection Based on Flux Transient Characteristics — Research Paper | ScholarLens