2017•Food and Agricultural ImmunologyOpen access

Production of antibodies and development of an enzyme-linked immunosorbent assay for 17β-estradiol in milk

Yu Bai, Jingyan Hu, Suzhen Liu, Weiyi Zhang, Jing Zhang, Jie He, Peide Li, Xiuhong Li, Junjie Jin, Zhanhui Wang

Open full text 24 citations

Abstract

The residue of 17β-estradiol (E2) in milk could potentially lead to the occurrence of various reproductive diseases; therefore, a rapid and sensitive method for monitoring E2 residues in milk was highly necessary. In this study, we produced new polyclonal and monoclonal antibodies using E2-3-O-carboxymethyl ether as a hapten and developed an indirect competitive enzyme-linked immunosorbent assay (icELISA) for the detection of E2 in milk. The results showed that the sensitivity of polyclonal antibody was higher than that of monoclonal antibody, providing a half maximum inhibition concentration (IC50) against E2 of 0.17 ng/mL, high cross-reactivity (CR) to E2 benzoate (150%) and oestriol (18.02%), and negligible CR with other oestrogen compounds. Under optimized conditions, the developed icELISA based on the polyclonal antibody had a limit of detection values of 0.093 μg/L, which was enough sensitive to detect E2 in milk. In spiked samples (0.5, 1, and 2 μg/L), the recoveries ranged from 83.12% to 94.58% with coefficients of variation <12.8%. These results indicated that the icELISA method we developed was suitable for screening of E2 residue in milk.

Open-access reader

About this research paper

What this paper is about

The residue of 17β-estradiol (E2) in milk could potentially lead to the occurrence of various reproductive diseases; therefore, a rapid and sensitive method for monitoring E2 residues in milk was highly necessary. In this study, we produced new polyclonal and monoclonal antibodies using E2-3-O-carboxymethyl ether as a hapten and developed an indirect competitive enzyme-linked immunosorbent assay (icELISA) for the detection of E2 in milk. The results showed that the sensitivity of polyclonal antibody was higher than that of monoclonal antibody, providing a half maximum inhibition concentration (IC50) against E2 of 0.17 ng/mL, high cross-reactivity (CR) to E2 benzoate (150%) and oestriol (18.02%), and negligible CR with other oestrogen compounds. Under optimized conditions, the developed icELISA based on the polyclonal antibody had a limit of detection values of 0.093 μg/L, which was enough sensitive to detect E2 in milk. In spiked samples (0.5, 1, and 2 μg/L), the recoveries ranged from 83.12% to 94.58% with coefficients of variation <12.8%. These results indicated that the icELISA method we developed was suitable for screening of E2 residue in milk.

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The residue of 17β-estradiol (E2) in milk could potentially lead to the occurrence of various reproductive diseases; therefore, a rapid and sensitive method for monitoring E2 residues in milk was highly necessary. In this study, we produced new polyclonal and monoclonal antibodies using E2-3-O-carboxymethyl ether as a hapten and developed an indirect competitive enzyme-linked immunosorbent assay (icELISA) for the detection of E2 in milk. The results showed that the sensitivity of polyclonal antibody was higher than that of monoclonal antibody, providing a half maximum inhibition concentration (IC50) against E2 of 0.17 ng/mL, high cross-reactivity (CR) to E2 benzoate (150%) and oestriol (18.02%), and negligible CR with other oestrogen compounds. Under optimized conditions, the developed icELISA based on the polyclonal antibody had a limit of detection values of 0.093 μg/L, which was enough sensitive to detect E2 in milk. In spiked samples (0.5, 1, and 2 μg/L), the recoveries ranged from 83.12% to 94.58% with coefficients of variation <12.8%. These results indicated that the icELISA method we developed was suitable for screening of E2 residue in milk.

Key concepts: Polyclonal antibodies, Hapten, Chemistry, Chromatography, Monoclonal antibody, Detection limit, Antibody, Residue (chemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Production of antibodies and development of an enzyme-linked immunosorbent assay for 17β-estradiol in milk — Research Paper | ScholarLens