2017Acta ChromatographicaOpen access

Development of UPLC–MS/MS method for quantitative analysis of curcumin in human plasma

Hayun Hayun, Rina Fitriana Rahmawati, Yahdiana Harahap, Santi Purna Sari

Open full text 10 citations

Abstract

A specific, very rapid, and sensitive ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method for quantitative analysis of curcumin in human plasma has been developed and validated. Diazepam was used as internal standard (IS). The analytes were isolated using liquid–liquid extraction method with the mixture of ethyl acetate–methanol (95:5). The organic solvents were evaporated, reconstituted in mobile phase, and injected to UPLC completed with UPLC BEH C18 column 1.7 μm, 2.1 × 100 mm Acquity® Waters as stationary phase, mixture of 0.15% formic acid–acetonitril (50:50, v/v) as mobile phase, and flow rate of 0.5 mL/min and detected in positive ionization mode tandem mass spectrometer operated in multiple reaction monitoring (MRM). The MS/MS ion transitions monitored were m/z 369.05 → 176.95 and 284.95 → 193 for curcumin and IS, respectively. The retention times for curcumin and IS were 1.7 and 1.4 min, respectively, and the linearity range was 1–100 ng/mL with a coefficient correlation (r) of 0.999 and lower limit of quantitation (LLOQ) of 1 ng/mL. The relative standard deviation (RSD) values of the intra- and inter-assay precisions of the method were below 8.3% and 12.7%, respectively, while the accuracy ranged from 89.5 to 98.7% and the extraction recovery of curcumin and IS was up to 86.6%. The data presented show that the method provides specific, very rapid, sensitive, precise, and accurate measurements of curcumin concentrations in human plasma.

Open-access reader

About this research paper

What this paper is about

A specific, very rapid, and sensitive ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method for quantitative analysis of curcumin in human plasma has been developed and validated. Diazepam was used as internal standard (IS). The analytes were isolated using liquid–liquid extraction method with the mixture of ethyl acetate–methanol (95:5). The organic solvents were evaporated, reconstituted in mobile phase, and injected to UPLC completed with UPLC BEH C18 column 1.7 μm, 2.1 × 100 mm Acquity® Waters as stationary phase, mixture of 0.15% formic acid–acetonitril (50:50, v/v) as mobile phase, and flow rate of 0.5 mL/min and detected in positive ionization mode tandem mass spectrometer operated in multiple reaction monitoring (MRM). The MS/MS ion transitions monitored were m/z 369.05 → 176.95 and 284.95 → 193 for curcumin and IS, respectively. The retention times for curcumin and IS were 1.7 and 1.4 min, respectively, and the linearity range was 1–100 ng/mL with a coefficient correlation (r) of 0.999 and lower limit of quantitation (LLOQ) of 1 ng/mL. The relative standard deviation (RSD) values of the intra- and inter-assay precisions of the method were below 8.3% and 12.7%, respectively, while the accuracy ranged from 89.5 to 98.7% and the extraction recovery of curcumin and IS was up to 86.6%. The data presented show that the method provides specific, very rapid, sensitive, precise, and accurate measurements of curcumin concentrations in human plasma.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A specific, very rapid, and sensitive ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method for quantitative analysis of curcumin in human plasma has been developed and validated. Diazepam was used as internal standard (IS). The analytes were isolated using liquid–liquid extraction method with the mixture of ethyl acetate–methanol (95:5). The organic solvents were evaporated, reconstituted in mobile phase, and injected to UPLC completed with UPLC BEH C18 column 1.7 μm, 2.1 × 100 mm Acquity® Waters as stationary phase, mixture of 0.15% formic acid–acetonitril (50:50, v/v) as mobile phase, and flow rate of 0.5 mL/min and detected in positive ionization mode tandem mass spectrometer operated in multiple reaction monitoring (MRM). The MS/MS ion transitions monitored were m/z 369.05 → 176.95 and 284.95 → 193 for curcumin and IS, respectively. The retention times for curcumin and IS were 1.7 and 1.4 min, respectively, and the linearity range was 1–100 ng/mL with a coefficient correlation (r) of 0.999 and lower limit of quantitation (LLOQ) of 1 ng/mL. The relative standard deviation (RSD) values of the intra- and inter-assay precisions of the method were below 8.3% and 12.7%, respectively, while the accuracy ranged from 89.5 to 98.7% and the extraction recovery of curcumin and IS was up to 86.6%. The data presented show that the method provides specific, very rapid, sensitive, precise, and accurate measurements of curcumin concentrations in human plasma.

Key concepts: Chemistry, Chromatography, Formic acid, High-performance liquid chromatography, Selected reaction monitoring, Curcumin, Extraction (chemistry), Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of UPLC–MS/MS method for quantitative analysis of curcumin in human plasma — Research Paper | ScholarLens