1983•Japanese Journal of Radiological TechnologyOpen access

RECIPROCITY-LAW FAILURE IN GREEN-SENSITIVE X-RAY FILM SYSTEM (Lanex Medium+OH-1) : DEVELOPMENT TEMPERATURE

SEISHI DODANUKI, Nobuyuki Moribe, Yoshio Sonoda, Yoshiharu Higashida, AKIYOSHI OHTSUKA

Open full text 0 citations

Abstract

Reciprocity-Law failure leads to increased patient exposure in clinical radiography and affects the image quality of a radiograph. A green sensitive X-ray film was developed by an automatic processor at three different temperatures of 33℃, 35℃, and 37℃ respectively, and the reciprocity-law failure of the film was measured under these conditions. As a result, it has been found that reciprocity-law failure is more likely to occur at higher development temperature and lower density than at lower development temperature and higher density.

Open-access reader

About this research paper

What this paper is about

Reciprocity-Law failure leads to increased patient exposure in clinical radiography and affects the image quality of a radiograph. A green sensitive X-ray film was developed by an automatic processor at three different temperatures of 33℃, 35℃, and 37℃ respectively, and the reciprocity-law failure of the film was measured under these conditions. As a result, it has been found that reciprocity-law failure is more likely to occur at higher development temperature and lower density than at lower development temperature and higher density.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Reciprocity-Law failure leads to increased patient exposure in clinical radiography and affects the image quality of a radiograph. A green sensitive X-ray film was developed by an automatic processor at three different temperatures of 33℃, 35℃, and 37℃ respectively, and the reciprocity-law failure of the film was measured under these conditions. As a result, it has been found that reciprocity-law failure is more likely to occur at higher development temperature and lower density than at lower development temperature and higher density.