1998Japanese Journal of Radiological TechnologyOpen access

Influenece of the Susceptibility Effect on Fast Spin Echo MR Imaging : Comparison of Image Distortion in Fast Spin Echo and Conventional Spin Echo Sequences

Toshio Tsuchihashi, Toshio Maki, Isao Fujita, Takeshi Suzuki

Open full text 0 citations

Abstract

Image distortion caused by the susceptibility effect was compared using fast spin echo (FSE) and conventional spin echo (CSE) sequences. When the sampling bandwidth for FSE and CSE was equal, there was no diffference in image distortion. Furthermore, image distortion for the two methods remained the same when echo train length (FTL) and echo space (ES) were changed. Image distortion caused by the susceptibility effect was greatly influenced by the sampling bandwidth for both FSE and CSE imaging. This indicated that the strength of the frequency encoding gradient (readout gradient) at data collection had a considerable effect on image distortion.

Open-access reader

About this research paper

What this paper is about

Image distortion caused by the susceptibility effect was compared using fast spin echo (FSE) and conventional spin echo (CSE) sequences. When the sampling bandwidth for FSE and CSE was equal, there was no diffference in image distortion. Furthermore, image distortion for the two methods remained the same when echo train length (FTL) and echo space (ES) were changed. Image distortion caused by the susceptibility effect was greatly influenced by the sampling bandwidth for both FSE and CSE imaging. This indicated that the strength of the frequency encoding gradient (readout gradient) at data collection had a considerable effect on image distortion.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Image distortion caused by the susceptibility effect was compared using fast spin echo (FSE) and conventional spin echo (CSE) sequences. When the sampling bandwidth for FSE and CSE was equal, there was no diffference in image distortion. Furthermore, image distortion for the two methods remained the same when echo train length (FTL) and echo space (ES) were changed. Image distortion caused by the susceptibility effect was greatly influenced by the sampling bandwidth for both FSE and CSE imaging. This indicated that the strength of the frequency encoding gradient (readout gradient) at data collection had a considerable effect on image distortion.

Key concepts: Distortion (music), Fast spin echo, Echo (communications protocol), Spin echo, k-space, Nuclear magnetic resonance, Sampling (signal processing), Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Influenece of the Susceptibility Effect on Fast Spin Echo MR Imaging : Comparison of Image Distortion in Fast Spin Echo and Conventional Spin Echo Sequences — Research Paper | ScholarLens