2011•Chalmers Publication Library (Chalmers University of Technology)Open access

An Analytical Method to Calculate Borehole Fluid Temperatures for Time-scales from Minutes to Decades

Johan Claesson, Saqib Javed

Open full text 188 citations

Abstract

Knowledge of borehole exit fluid temperature is required to optimize the design and performance of ground source heat pump systems. The borehole exit fluid temperature depends upon the prescribed heat injection and extraction rates. This paper presents a method to determine the fluid temperature of a single or a multiple borehole heat exchanger for any prescribed heat injection or extraction rate. The fluid temperature, from minutes to decades, is determined using step response functions. An analytical radial solution is used for shorter times. A finite line-source solution is used for longer times. The line-source response function has been reduced to one integral only. The derivative, the weighting function, is given by an explicit formula both for single boreholes and any configuration of vertical boreholes.

Open-access reader

About this research paper

What this paper is about

Knowledge of borehole exit fluid temperature is required to optimize the design and performance of ground source heat pump systems. The borehole exit fluid temperature depends upon the prescribed heat injection and extraction rates. This paper presents a method to determine the fluid temperature of a single or a multiple borehole heat exchanger for any prescribed heat injection or extraction rate. The fluid temperature, from minutes to decades, is determined using step response functions. An analytical radial solution is used for shorter times. A finite line-source solution is used for longer times. The line-source response function has been reduced to one integral only. The derivative, the weighting function, is given by an explicit formula both for single boreholes and any configuration of vertical boreholes.

Why it matters

OpenAlex reports 188 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Knowledge of borehole exit fluid temperature is required to optimize the design and performance of ground source heat pump systems. The borehole exit fluid temperature depends upon the prescribed heat injection and extraction rates. This paper presents a method to determine the fluid temperature of a single or a multiple borehole heat exchanger for any prescribed heat injection or extraction rate. The fluid temperature, from minutes to decades, is determined using step response functions. An analytical radial solution is used for shorter times. A finite line-source solution is used for longer times. The line-source response function has been reduced to one integral only. The derivative, the weighting function, is given by an explicit formula both for single boreholes and any configuration of vertical boreholes.

Key concepts: Borehole, Line source, Weighting, Heat exchanger, Working fluid, Extraction (chemistry), Mechanics, Heat pump

Related papers

Back to paper searchBrowse research topicsOriginal source
An Analytical Method to Calculate Borehole Fluid Temperatures for Time-scales from Minutes to Decades — Research Paper | ScholarLens