2017Engineering JournalOpen access

Evaluation of Micellar-Enhanced Ultrafiltration (MEUF) Membrane for Dye Removal of Synthetic Remazol Dye Wastewater

Nita Aryanti, Fathikatul K. Ika Sandria, Reza Harena Putriadi, Dyah Hesti Wardhani

Open full text 15 citations

Abstract

Micellar-Enhanced Ultrafiltration Membrane (MEUF) is one of promising technology to separate low molecular weight substances such as dyes.The MEUF process involves a combination of ultrafiltration and surfactant at a concentration higher than surfactant's Critical Micelle Concentration (CMC).This research was focused on the application of MEUF for synthetic Remazol dye wastewater containing Remazol Yellow/Black B/ Turquoise Blue at different dye concentration.In the MEUF system, a PolyEther Sulphone Ultrafiltration membrane and Cetyl Pyridinum Chloride (CPC) surfactant at concentration of 2 times of its Critical Micelle Concentration were used.Evaluation of MEUF performance was determined based on flux profile and rejection.It was confirmed that dye concentration did not change the flux profile significantly.Flux reduction was effected by the addition of surfactant in the MEUF system.Flux decline in the MEUF was due to the formation of surfactant micelle aggregates with dye generating a deposited layer on the membrane surface.As the CPC is an ionic surfactant, the formation of the micelle is attributed to a balance between the attraction of hydrocarbon chain (hydrophobic tail) and ionic repulsion.Scanning Electron Microscopy images verified that there was an additional layer on the membrane surface after MEUF was performed, indicating a deposited layer.The permeate rejections were more than 70% and 96% for rejection of Chemical Oxygen Demand and Remazol dye, respectively.The rejection of dye ion and Chemical Oxygen Demand were attributed due to anionic dye solubilization in the surfactant micelles.The solubilization was formed by adsorbtion through electrostatic attraction.

Open-access reader

About this research paper

What this paper is about

Micellar-Enhanced Ultrafiltration Membrane (MEUF) is one of promising technology to separate low molecular weight substances such as dyes.The MEUF process involves a combination of ultrafiltration and surfactant at a concentration higher than surfactant's Critical Micelle Concentration (CMC).This research was focused on the application of MEUF for synthetic Remazol dye wastewater containing Remazol Yellow/Black B/ Turquoise Blue at different dye concentration.In the MEUF system, a PolyEther Sulphone Ultrafiltration membrane and Cetyl Pyridinum Chloride (CPC) surfactant at concentration of 2 times of its Critical Micelle Concentration were used.Evaluation of MEUF performance was determined based on flux profile and rejection.It was confirmed that dye concentration did not change the flux profile significantly.Flux reduction was effected by the addition of surfactant in the MEUF system.Flux decline in the MEUF was due to the formation of surfactant micelle aggregates with dye generating a deposited layer on the membrane surface.As the CPC is an ionic surfactant, the formation of the micelle is attributed to a balance between the attraction of hydrocarbon chain (hydrophobic tail) and ionic repulsion.Scanning Electron Microscopy images verified that there was an additional layer on the membrane surface after MEUF was performed, indicating a deposited layer.The permeate rejections were more than 70% and 96% for rejection of Chemical Oxygen Demand and Remazol dye, respectively.The rejection of dye ion and Chemical Oxygen Demand were attributed due to anionic dye solubilization in the surfactant micelles.The solubilization was formed by adsorbtion through electrostatic attraction.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Micellar-Enhanced Ultrafiltration Membrane (MEUF) is one of promising technology to separate low molecular weight substances such as dyes.The MEUF process involves a combination of ultrafiltration and surfactant at a concentration higher than surfactant's Critical Micelle Concentration (CMC).This research was focused on the application of MEUF for synthetic Remazol dye wastewater containing Remazol Yellow/Black B/ Turquoise Blue at different dye concentration.In the MEUF system, a PolyEther Sulphone Ultrafiltration membrane and Cetyl Pyridinum Chloride (CPC) surfactant at concentration of 2 times of its Critical Micelle Concentration were used.Evaluation of MEUF performance was determined based on flux profile and rejection.It was confirmed that dye concentration did not change the flux profile significantly.Flux reduction was effected by the addition of surfactant in the MEUF system.Flux decline in the MEUF was due to the formation of surfactant micelle aggregates with dye generating a deposited layer on the membrane surface.As the CPC is an ionic surfactant, the formation of the micelle is attributed to a balance between the attraction of hydrocarbon chain (hydrophobic tail) and ionic repulsion.Scanning Electron Microscopy images verified that there was an additional layer on the membrane surface after MEUF was performed, indicating a deposited layer.The permeate rejections were more than 70% and 96% for rejection of Chemical Oxygen Demand and Remazol dye, respectively.The rejection of dye ion and Chemical Oxygen Demand were attributed due to anionic dye solubilization in the surfactant micelles.The solubilization was formed by adsorbtion through electrostatic attraction.

Key concepts: Ultrafiltration (renal), Wastewater, Membrane, Reactive dye, Chromatography, Chemistry, Pulp and paper industry, Environmental engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of Micellar-Enhanced Ultrafiltration (MEUF) Membrane for Dye Removal of Synthetic Remazol Dye Wastewater — Research Paper | ScholarLens