2006Brazilian Journal of OtorhinolaryngologyOpen access

Identifying dead regions in the cochlea through the TEN Test

Regina Tangerino de Souza Jacob, João Cândido Fernandes, Jair Manfrinato, Maria Cecília Martinelli Iório

Open full text 6 citations

Abstract

UNLABELLED: An audiogram is not sufficient to indicate cochlear dead regions. AIM: To investigate cochlear dead regions in sensorineural hearing loss subjects using the TEN test. SITE: CEDALVI/ HRAC-USP-Bauru/Sao Paulo/Brazil, August 2003 to February 2004. STUDY DESIGN: A contemporary cross-sectional cohort study. MATERIAL AND METHODS: The TEN test was applied in three groups: G1(5 women with pure-tone thresholds within normal limits); G2(4 women and 5 men with moderate sensorineural flat hearing loss); G3(19 women and 24 men with mild to severe sloping sensorineural hearing loss). RESULTS: In the G1 group the TEN value required to eliminate the test tone was, on average, close to the absolute threshold for all frequencies. No dead regions were found in the ears tested in group G2. 76 ears were tested in group G3, and six showed no evidence of dead regions in the cochlea. CONCLUSIONS: The TEN test was an effective test to indicate a dead region in the cochlea of subjects with sloping sensorineural hearing loss. There is evidence that pure-tone detection is different for subjects with high frequency sensorineural hearing loss and flat hearing loss; we observed a significant difference between the masked threshold and the absolute threshold only in sloping hearing loss and not for flat hearing loss.

Open-access reader

About this research paper

What this paper is about

UNLABELLED: An audiogram is not sufficient to indicate cochlear dead regions. AIM: To investigate cochlear dead regions in sensorineural hearing loss subjects using the TEN test. SITE: CEDALVI/ HRAC-USP-Bauru/Sao Paulo/Brazil, August 2003 to February 2004. STUDY DESIGN: A contemporary cross-sectional cohort study. MATERIAL AND METHODS: The TEN test was applied in three groups: G1(5 women with pure-tone thresholds within normal limits); G2(4 women and 5 men with moderate sensorineural flat hearing loss); G3(19 women and 24 men with mild to severe sloping sensorineural hearing loss). RESULTS: In the G1 group the TEN value required to eliminate the test tone was, on average, close to the absolute threshold for all frequencies. No dead regions were found in the ears tested in group G2. 76 ears were tested in group G3, and six showed no evidence of dead regions in the cochlea. CONCLUSIONS: The TEN test was an effective test to indicate a dead region in the cochlea of subjects with sloping sensorineural hearing loss. There is evidence that pure-tone detection is different for subjects with high frequency sensorineural hearing loss and flat hearing loss; we observed a significant difference between the masked threshold and the absolute threshold only in sloping hearing loss and not for flat hearing loss.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

UNLABELLED: An audiogram is not sufficient to indicate cochlear dead regions. AIM: To investigate cochlear dead regions in sensorineural hearing loss subjects using the TEN test. SITE: CEDALVI/ HRAC-USP-Bauru/Sao Paulo/Brazil, August 2003 to February 2004. STUDY DESIGN: A contemporary cross-sectional cohort study. MATERIAL AND METHODS: The TEN test was applied in three groups: G1(5 women with pure-tone thresholds within normal limits); G2(4 women and 5 men with moderate sensorineural flat hearing loss); G3(19 women and 24 men with mild to severe sloping sensorineural hearing loss). RESULTS: In the G1 group the TEN value required to eliminate the test tone was, on average, close to the absolute threshold for all frequencies. No dead regions were found in the ears tested in group G2. 76 ears were tested in group G3, and six showed no evidence of dead regions in the cochlea. CONCLUSIONS: The TEN test was an effective test to indicate a dead region in the cochlea of subjects with sloping sensorineural hearing loss. There is evidence that pure-tone detection is different for subjects with high frequency sensorineural hearing loss and flat hearing loss; we observed a significant difference between the masked threshold and the absolute threshold only in sloping hearing loss and not for flat hearing loss.

Key concepts: Audiology, Audiogram, Hearing loss, Sensorineural hearing loss, Cochlea, Medicine, Absolute threshold, Tone (literature)

Related papers

Back to paper searchBrowse research topicsOriginal source
Identifying dead regions in the cochlea through the TEN Test — Research Paper | ScholarLens