2017Automation technological and business processesOpen access

IMPROVED MODELS AND METHOD OF POWER CHANGE OF NPP UNIT WITH VVER-1000

T. Foshch, S.N. Pelykh

Open full text 7 citations

Abstract

This study represents the improved mathematical and imitational allocated in space multi-zone model of VVER-1000 which differs from the known one. It allows to take into account the energy release of 235U nuclei fission as well as 239Pu . Moreover, this model includes sub-models of simultaneous control impact of the boric acid concentration in the coolant of the first circuit and the position of 9th group control rods which allows to consider it as the model with allocated parameters and also allows to monitor changes in the mentioned technological parameters by reactor core symmetry sectors, by layers of reactor core height and by fuel assembly group each symmetry sector. Moreover, this model allows to calculate important process-dependent parameters of the reactor (including axial offset) as quantitative measure of its safety. As the mathematical and imitational models were improved, it allows to take into account intrinsic properties of the reactor core (including transient processes of xenon) and thus reduce the error of modelling static and dynamic properties of the reactor.The automated control method of power change of the NPP unit with VVER-1000 was proposed for the first time. It uses three control loops. One of which maintains the regulatory change of reactor power by regulating the concentration of boric acid in the coolant, the second circuit keeps the required value of axial offset by changing the position of control rods, and the third one holds constant the coolant temperature mode by regulating the position of the main turbo generator valves.On the basis of the above obtained method, two control programs were improved. The first one is the improved control program that implements the constant temperature of the coolant in the first circuit and the second one is the improved control program that implements the constant steam pressure in the second circuit.

Open-access reader

About this research paper

What this paper is about

This study represents the improved mathematical and imitational allocated in space multi-zone model of VVER-1000 which differs from the known one. It allows to take into account the energy release of 235U nuclei fission as well as 239Pu . Moreover, this model includes sub-models of simultaneous control impact of the boric acid concentration in the coolant of the first circuit and the position of 9th group control rods which allows to consider it as the model with allocated parameters and also allows to monitor changes in the mentioned technological parameters by reactor core symmetry sectors, by layers of reactor core height and by fuel assembly group each symmetry sector. Moreover, this model allows to calculate important process-dependent parameters of the reactor (including axial offset) as quantitative measure of its safety. As the mathematical and imitational models were improved, it allows to take into account intrinsic properties of the reactor core (including transient processes of xenon) and thus reduce the error of modelling static and dynamic properties of the reactor.The automated control method of power change of the NPP unit with VVER-1000 was proposed for the first time. It uses three control loops. One of which maintains the regulatory change of reactor power by regulating the concentration of boric acid in the coolant, the second circuit keeps the required value of axial offset by changing the position of control rods, and the third one holds constant the coolant temperature mode by regulating the position of the main turbo generator valves.On the basis of the above obtained method, two control programs were improved. The first one is the improved control program that implements the constant temperature of the coolant in the first circuit and the second one is the improved control program that implements the constant steam pressure in the second circuit.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study represents the improved mathematical and imitational allocated in space multi-zone model of VVER-1000 which differs from the known one. It allows to take into account the energy release of 235U nuclei fission as well as 239Pu . Moreover, this model includes sub-models of simultaneous control impact of the boric acid concentration in the coolant of the first circuit and the position of 9th group control rods which allows to consider it as the model with allocated parameters and also allows to monitor changes in the mentioned technological parameters by reactor core symmetry sectors, by layers of reactor core height and by fuel assembly group each symmetry sector. Moreover, this model allows to calculate important process-dependent parameters of the reactor (including axial offset) as quantitative measure of its safety. As the mathematical and imitational models were improved, it allows to take into account intrinsic properties of the reactor core (including transient processes of xenon) and thus reduce the error of modelling static and dynamic properties of the reactor.The automated control method of power change of the NPP unit with VVER-1000 was proposed for the first time. It uses three control loops. One of which maintains the regulatory change of reactor power by regulating the concentration of boric acid in the coolant, the second circuit keeps the required value of axial offset by changing the position of control rods, and the third one holds constant the coolant temperature mode by regulating the position of the main turbo generator valves.On the basis of the above obtained method, two control programs were improved. The first one is the improved control program that implements the constant temperature of the coolant in the first circuit and the second one is the improved control program that implements the constant steam pressure in the second circuit.

Key concepts: VVER, Control rod, Coolant, Nuclear reactor core, Offset (computer science), Nuclear engineering, Pressurized water reactor, Turbo generator

Related papers

Back to paper searchBrowse research topicsOriginal source
IMPROVED MODELS AND METHOD OF POWER CHANGE OF NPP UNIT WITH VVER-1000 — Research Paper | ScholarLens