2016•The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)Open access

Study on an ECF micropump-integrated microhand composed of eccentric tube type microactuators

Yoshiaki SAGA, Joon-wan KIM, Shinichi YOKOTA, Kazuya EDAMURA

Open full text 0 citations

Abstract

Microactuators driven by fluid have been developed. This paper presents an eccentric tube type microactuator having ECF micropump inside and applies to a novel microhand. First, an eccentric tube type microactuator was made by high precision molding of PDMS. Second, the ECF micropump was designed for high output pressure and fabricated by MEMS technology. The size is 10×10 mm2 and the electrodes (TPSEs) are serially cascaded in 88 electrode pairs. The characteristics of the ECF micropump are experimentally investigated. The output pressure without flow was 78.3 kPa, while the flow rate without load pressure was 23.3 mm3/s at 1.25 kV. Last, we formed a novel microhand composed of three eccentric tube type microactuators, ECF micropump and fluidic channel parts. Three fingers are stuck together at 0.75 kV. As the dynamic characteristics, the edge time with voltage-on and voltage-off are 1.8 s and 0.6 s at 0.72 kV, respectively.

Open-access reader

About this research paper

What this paper is about

Microactuators driven by fluid have been developed. This paper presents an eccentric tube type microactuator having ECF micropump inside and applies to a novel microhand. First, an eccentric tube type microactuator was made by high precision molding of PDMS. Second, the ECF micropump was designed for high output pressure and fabricated by MEMS technology. The size is 10×10 mm2 and the electrodes (TPSEs) are serially cascaded in 88 electrode pairs. The characteristics of the ECF micropump are experimentally investigated. The output pressure without flow was 78.3 kPa, while the flow rate without load pressure was 23.3 mm3/s at 1.25 kV. Last, we formed a novel microhand composed of three eccentric tube type microactuators, ECF micropump and fluidic channel parts. Three fingers are stuck together at 0.75 kV. As the dynamic characteristics, the edge time with voltage-on and voltage-off are 1.8 s and 0.6 s at 0.72 kV, respectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Microactuators driven by fluid have been developed. This paper presents an eccentric tube type microactuator having ECF micropump inside and applies to a novel microhand. First, an eccentric tube type microactuator was made by high precision molding of PDMS. Second, the ECF micropump was designed for high output pressure and fabricated by MEMS technology. The size is 10×10 mm2 and the electrodes (TPSEs) are serially cascaded in 88 electrode pairs. The characteristics of the ECF micropump are experimentally investigated. The output pressure without flow was 78.3 kPa, while the flow rate without load pressure was 23.3 mm3/s at 1.25 kV. Last, we formed a novel microhand composed of three eccentric tube type microactuators, ECF micropump and fluidic channel parts. Three fingers are stuck together at 0.75 kV. As the dynamic characteristics, the edge time with voltage-on and voltage-off are 1.8 s and 0.6 s at 0.72 kV, respectively.

Key concepts: Microactuator, Micropump, Materials science, Voltage, Electrode, Tube (container), Microelectromechanical systems, Volumetric flow rate

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on an ECF micropump-integrated microhand composed of eccentric tube type microactuators — Research Paper | ScholarLens