2017SUNScholar (Stellenbosch University)Open access

Heliostat Cost Reduction for Power Tower Plants

Arvind Pidaparthi

Open full text 7 citations

Abstract

Heliostats typically contribute to about 40 % of the total installed costs in a concentrated solar power (CSP) tower plant.The objective of this study is to investigate the effects of heliostat size on the levelized cost of electricity (LCOE).These effects are analysed in a power tower with a net capacity of 100 MWe with 8 hours of thermal energy storage in Upington, South Africa.A large, medium and a small sized heliostat with a total area of 115.56 m 2 , 43.33 m 2 and 16.69 m 2 respectively are considered for comparison.The heliostat cost per unit is calculated separately for the three different heliostat sizes and the effects due to size scaling, learning curve benefits and the price index is considered.The annual operation and maintenance (O&M) costs are estimated separately for the three heliostat fields, where the number of personnel required in the field is determined by the number of heliostats in the field.The LCOE values are used as a figure of merit to compare the different heliostat sizes.The lowest theoretical LCOE value of 0.1960 $/kWhe is achieved using the medium size heliostat with an area of 43.33 m 2 for this power tower configuration.

Open-access reader

About this research paper

What this paper is about

Heliostats typically contribute to about 40 % of the total installed costs in a concentrated solar power (CSP) tower plant.The objective of this study is to investigate the effects of heliostat size on the levelized cost of electricity (LCOE).These effects are analysed in a power tower with a net capacity of 100 MWe with 8 hours of thermal energy storage in Upington, South Africa.A large, medium and a small sized heliostat with a total area of 115.56 m 2 , 43.33 m 2 and 16.69 m 2 respectively are considered for comparison.The heliostat cost per unit is calculated separately for the three different heliostat sizes and the effects due to size scaling, learning curve benefits and the price index is considered.The annual operation and maintenance (O&M) costs are estimated separately for the three heliostat fields, where the number of personnel required in the field is determined by the number of heliostats in the field.The LCOE values are used as a figure of merit to compare the different heliostat sizes.The lowest theoretical LCOE value of 0.1960 $/kWhe is achieved using the medium size heliostat with an area of 43.33 m 2 for this power tower configuration.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Heliostats typically contribute to about 40 % of the total installed costs in a concentrated solar power (CSP) tower plant.The objective of this study is to investigate the effects of heliostat size on the levelized cost of electricity (LCOE).These effects are analysed in a power tower with a net capacity of 100 MWe with 8 hours of thermal energy storage in Upington, South Africa.A large, medium and a small sized heliostat with a total area of 115.56 m 2 , 43.33 m 2 and 16.69 m 2 respectively are considered for comparison.The heliostat cost per unit is calculated separately for the three different heliostat sizes and the effects due to size scaling, learning curve benefits and the price index is considered.The annual operation and maintenance (O&M) costs are estimated separately for the three heliostat fields, where the number of personnel required in the field is determined by the number of heliostats in the field.The LCOE values are used as a figure of merit to compare the different heliostat sizes.The lowest theoretical LCOE value of 0.1960 $/kWhe is achieved using the medium size heliostat with an area of 43.33 m 2 for this power tower configuration.

Key concepts: Heliostat, Cost of electricity by source, Environmental science, Tower, Power station, Electricity generation, Power (physics), Meteorology

Related papers

Back to paper searchBrowse research topicsOriginal source
Heliostat Cost Reduction for Power Tower Plants — Research Paper | ScholarLens