Cooling Load Estimation in the Building Based On Heat Sources
Chairani, Selo Sulistyo, Widyawan Widyawan
Abstract
Open-access reader
Chairani, Selo Sulistyo, Widyawan Widyawan
Abstract
Open-access reader
Heating, ventilation and air conditioning (HVAC) is the largest source of energy consumption. In this research, we discuss cooling load in the room by considering the different heat source and the number of occupancy. Energy cooling load is affected by external and internal heat sources. External cooling load in this discussion include convection outdoor/exterior using the DOE-2 algorithm, calculation of heat using Thermal Analysis Research Program (TARP), and Conduction Transfer Function (CTF). The internal cooling load is calculated based on the activity of the occupants in the office, a number of occupants, heat gain from lighting, and heat gain from electrics equipment. Weather data used is Surakarta weather and design day used is Jakarta design day. We use the ASHRAE standard for building materials and the metabolic of occupants while on the activity. The results show that the number of occupancies have an influence of cooling load. A large number of occupancy will cause the cooling load is great as well.
OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Heating, ventilation and air conditioning (HVAC) is the largest source of energy consumption. In this research, we discuss cooling load in the room by considering the different heat source and the number of occupancy. Energy cooling load is affected by external and internal heat sources. External cooling load in this discussion include convection outdoor/exterior using the DOE-2 algorithm, calculation of heat using Thermal Analysis Research Program (TARP), and Conduction Transfer Function (CTF). The internal cooling load is calculated based on the activity of the occupants in the office, a number of occupants, heat gain from lighting, and heat gain from electrics equipment. Weather data used is Surakarta weather and design day used is Jakarta design day. We use the ASHRAE standard for building materials and the metabolic of occupants while on the activity. The results show that the number of occupancies have an influence of cooling load. A large number of occupancy will cause the cooling load is great as well.
Key concepts: ASHRAE 90.1, Cooling load, HVAC, Occupancy, Environmental science, Air conditioning, Heat load, Internal heating