2004•Deep Blue (University of Michigan)Requires access

Ultrasound imaging guidance and evaluation in ultrasound therapy.

Jongbum Seo

Open publisher page 0 citations

Abstract

High intensity ultrasound can create hyperechoic regions in an ultrasound image due to local generation of bubbles. We explore the link between the temporal extent of these hyperechoic regions and tissue damage caused by ultrasound therapy. The decay rate of increased echogenicity from the focal zone in insonated live exteriorized canine kidney was quantified and correlated to the spatial extent of tissue damage. The decay half-time, thalf, defined as the time for echogenicity enhancement to decay by a factor of 2, was observed in all cases to be greater than 41 seconds in spatial zones where extensive histological damage was observed. In cases where the measured thalf was less than 11 seconds, the damage was limited to minor hemorrhage, or was not detected. These thalf discrimination boundaries of 41 and 11 seconds were not statistically different for cases where contrast agent was used to enhance therapeutic efficiency. Nonlinear beam mixing with microbubbles was explored to create a pseudo point source for aberration correction of therapeutic ultrasound. A damping coefficient for a bubble driven by a dual frequency sound field was derived by revisiting Prosperetti's damping model. As a result, the overall damping term for dual frequency operation was obtained by linear summation of two damping terms for each frequency. The numerical simulation based on the bubble model suggests that the most efficient size range to generate a 1 MHz frequency from 4 MHz and 5 MHz sound sources is 2.6--3.0 mum. Furthermore, this range constitutes the primary distribution of a specific ultrasound contrast agent: Optison. When a chamber of 0.1% diluted Option was sonified by 4 and 5 MHz sound beams with 80° incident angle between them, an approximately 100 Pa, 1 MHz frequency signal can be measured approximately 10 cm away. Furthermore, the received 1 MHz difference frequency signal shows omni-directional characteristics, even though the overlap zone of the two sound beams is on the order of the difference frequency wavelength. Therefore, the induced sound source can be considered as a pseudo point source and is expected to be useful for aberration correction for therapeutic ultrasound.

About this research paper

What this paper is about

High intensity ultrasound can create hyperechoic regions in an ultrasound image due to local generation of bubbles. We explore the link between the temporal extent of these hyperechoic regions and tissue damage caused by ultrasound therapy. The decay rate of increased echogenicity from the focal zone in insonated live exteriorized canine kidney was quantified and correlated to the spatial extent of tissue damage. The decay half-time, thalf, defined as the time for echogenicity enhancement to decay by a factor of 2, was observed in all cases to be greater than 41 seconds in spatial zones where extensive histological damage was observed. In cases where the measured thalf was less than 11 seconds, the damage was limited to minor hemorrhage, or was not detected. These thalf discrimination boundaries of 41 and 11 seconds were not statistically different for cases where contrast agent was used to enhance therapeutic efficiency. Nonlinear beam mixing with microbubbles was explored to create a pseudo point source for aberration correction of therapeutic ultrasound. A damping coefficient for a bubble driven by a dual frequency sound field was derived by revisiting Prosperetti's damping model. As a result, the overall damping term for dual frequency operation was obtained by linear summation of two damping terms for each frequency. The numerical simulation based on the bubble model suggests that the most efficient size range to generate a 1 MHz frequency from 4 MHz and 5 MHz sound sources is 2.6--3.0 mum. Furthermore, this range constitutes the primary distribution of a specific ultrasound contrast agent: Optison. When a chamber of 0.1% diluted Option was sonified by 4 and 5 MHz sound beams with 80° incident angle between them, an approximately 100 Pa, 1 MHz frequency signal can be measured approximately 10 cm away. Furthermore, the received 1 MHz difference frequency signal shows omni-directional characteristics, even though the overlap zone of the two sound beams is on the order of the difference frequency wavelength. Therefore, the induced sound source can be considered as a pseudo point source and is expected to be useful for aberration correction for therapeutic ultrasound.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

High intensity ultrasound can create hyperechoic regions in an ultrasound image due to local generation of bubbles. We explore the link between the temporal extent of these hyperechoic regions and tissue damage caused by ultrasound therapy. The decay rate of increased echogenicity from the focal zone in insonated live exteriorized canine kidney was quantified and correlated to the spatial extent of tissue damage. The decay half-time, thalf, defined as the time for echogenicity enhancement to decay by a factor of 2, was observed in all cases to be greater than 41 seconds in spatial zones where extensive histological damage was observed. In cases where the measured thalf was less than 11 seconds, the damage was limited to minor hemorrhage, or was not detected. These thalf discrimination boundaries of 41 and 11 seconds were not statistically different for cases where contrast agent was used to enhance therapeutic efficiency. Nonlinear beam mixing with microbubbles was explored to create a pseudo point source for aberration correction of therapeutic ultrasound. A damping coefficient for a bubble driven by a dual frequency sound field was derived by revisiting Prosperetti's damping model. As a result, the overall damping term for dual frequency operation was obtained by linear summation of two damping terms for each frequency. The numerical simulation based on the bubble model suggests that the most efficient size range to generate a 1 MHz frequency from 4 MHz and 5 MHz sound sources is 2.6--3.0 mum. Furthermore, this range constitutes the primary distribution of a specific ultrasound contrast agent: Optison. When a chamber of 0.1% diluted Option was sonified by 4 and 5 MHz sound beams with 80° incident angle between them, an approximately 100 Pa, 1 MHz frequency signal can be measured approximately 10 cm away. Furthermore, the received 1 MHz difference frequency signal shows omni-directional characteristics, even though the overlap zone of the two sound beams is on the order of the difference frequency wavelength. Therefore, the induced sound source can be considered as a pseudo point source and is expected to be useful for aberration correction for therapeutic ultrasound.

Key concepts: Ultrasound, Ultrasound imaging, Medicine, Medical physics, Ultrasound treatment, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Ultrasound imaging guidance and evaluation in ultrasound therapy. — Research Paper | ScholarLens