2016Journal of Optical TechnologyRequires access

Three-mirror interferometer of partially coherent light for monitoring surface relief

Е. В. Сысоев

Open publisher page 0 citations

Abstract

The interference of partially coherent light in a three-mirror interferometer with a low-coherence light source is analyzed. It is shown that a set of coherence layers (polyzonal interference) is formed when the distance between the two mirrors mounted in the interferometer’s reference arm is greater than the coherence length. An expression is obtained that describes the interference of partially coherent light in a three-mirror interferometer. The results of calculations, modeling, and experiments are presented.

About this research paper

What this paper is about

The interference of partially coherent light in a three-mirror interferometer with a low-coherence light source is analyzed. It is shown that a set of coherence layers (polyzonal interference) is formed when the distance between the two mirrors mounted in the interferometer’s reference arm is greater than the coherence length. An expression is obtained that describes the interference of partially coherent light in a three-mirror interferometer. The results of calculations, modeling, and experiments are presented.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The interference of partially coherent light in a three-mirror interferometer with a low-coherence light source is analyzed. It is shown that a set of coherence layers (polyzonal interference) is formed when the distance between the two mirrors mounted in the interferometer’s reference arm is greater than the coherence length. An expression is obtained that describes the interference of partially coherent light in a three-mirror interferometer. The results of calculations, modeling, and experiments are presented.

Key concepts: Interferometry, Interference (communication), Optics, Coherence (philosophical gambling strategy), Interferometric visibility, Physics, Coherence time, Coherence length