2017•Journal of Structural EngineeringRequires access

In-Plane Seismic Performance of Fully Grouted Reinforced Masonry Shear Walls

Hany M. Seif ElDin, Khaled E. Galal

Open publisher page 48 citations

Abstract

Reinforced masonry (RM) shear walls are key structural elements widely used to resist lateral loads in masonry buildings due to their capability to provide lateral strength, stiffness, and energy dissipation. This paper investigates the in-plane seismic performance of fully grouted RM shear walls dominated by shear failure. The experimental work involved assessing the response of five single-story RM shear walls when subjected to in-plane axial compressive stress, cyclic lateral excitations, and top moment. The studied parameters were the horizontal reinforcement ratio, level of axial compressive stress, and shear span to depth ratio. Most of the current provisions in masonry design codes for nominal in-plane shear strength, Vn, for RM shear walls consider a percentage of the yield capacity for the shear resistance provided by the horizontal reinforcement, Vs. Moreover, they limit the effect of the shear span to depth ratio, M/Vdv, to an upper value of 1.0. The test results concluded that the horizontal reinforcement could contribute 100% of its yield capacity toward Vn. In addition, increasing M/Vdv from 1.25 to 1.875 resulted in a significant reduction in the shear strength by 25%, which means that limiting the effect of M/Vdv to an upper value of 1.0 is overestimating Vn of RM shear walls at high values of M/Vdv. However, this reduction is accompanied by higher displacement ductility. On the other hand, increasing the axial compressive stress resulted in a higher Vn with more brittle failure.

About this research paper

What this paper is about

Reinforced masonry (RM) shear walls are key structural elements widely used to resist lateral loads in masonry buildings due to their capability to provide lateral strength, stiffness, and energy dissipation. This paper investigates the in-plane seismic performance of fully grouted RM shear walls dominated by shear failure. The experimental work involved assessing the response of five single-story RM shear walls when subjected to in-plane axial compressive stress, cyclic lateral excitations, and top moment. The studied parameters were the horizontal reinforcement ratio, level of axial compressive stress, and shear span to depth ratio. Most of the current provisions in masonry design codes for nominal in-plane shear strength, Vn, for RM shear walls consider a percentage of the yield capacity for the shear resistance provided by the horizontal reinforcement, Vs. Moreover, they limit the effect of the shear span to depth ratio, M/Vdv, to an upper value of 1.0. The test results concluded that the horizontal reinforcement could contribute 100% of its yield capacity toward Vn. In addition, increasing M/Vdv from 1.25 to 1.875 resulted in a significant reduction in the shear strength by 25%, which means that limiting the effect of M/Vdv to an upper value of 1.0 is overestimating Vn of RM shear walls at high values of M/Vdv. However, this reduction is accompanied by higher displacement ductility. On the other hand, increasing the axial compressive stress resulted in a higher Vn with more brittle failure.

Why it matters

OpenAlex reports 48 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Reinforced masonry (RM) shear walls are key structural elements widely used to resist lateral loads in masonry buildings due to their capability to provide lateral strength, stiffness, and energy dissipation. This paper investigates the in-plane seismic performance of fully grouted RM shear walls dominated by shear failure. The experimental work involved assessing the response of five single-story RM shear walls when subjected to in-plane axial compressive stress, cyclic lateral excitations, and top moment. The studied parameters were the horizontal reinforcement ratio, level of axial compressive stress, and shear span to depth ratio. Most of the current provisions in masonry design codes for nominal in-plane shear strength, Vn, for RM shear walls consider a percentage of the yield capacity for the shear resistance provided by the horizontal reinforcement, Vs. Moreover, they limit the effect of the shear span to depth ratio, M/Vdv, to an upper value of 1.0. The test results concluded that the horizontal reinforcement could contribute 100% of its yield capacity toward Vn. In addition, increasing M/Vdv from 1.25 to 1.875 resulted in a significant reduction in the shear strength by 25%, which means that limiting the effect of M/Vdv to an upper value of 1.0 is overestimating Vn of RM shear walls at high values of M/Vdv. However, this reduction is accompanied by higher displacement ductility. On the other hand, increasing the axial compressive stress resulted in a higher Vn with more brittle failure.

Key concepts: Masonry, Structural engineering, Shear (geology), Geotechnical engineering, Materials science, Compressive strength, Brittleness, Stiffness

Related papers

Back to paper searchBrowse research topicsOriginal source
In-Plane Seismic Performance of Fully Grouted Reinforced Masonry Shear Walls — Research Paper | ScholarLens