2015실내환경 및 냄새 학회지Requires access

혼잡영향에 따른 대중교통 차량 내 PM10과 CO2 농도 특성에 관한 연구

Joon-sig Jung, Soon-Bark Kwon, Kim Jong Bum, 김성연, Woo-seok Lee, Gwi–Nam Bae, Park Duck-Shin

Open publisher page 0 citations

Abstract

In this study, we investigated the concentrations of PM10 and CO2 in public transportation vehicles (express bus, train, KTX, and subway) reported by previous indoor air quality (IAQ) surveys carried out from 2005 to 2013 in Korea. The number of valid data for PM10 was 566 and for CO2 was 579, and all data were classified according to whether it was collected during rush-hour or non rush-hour. PM10 and CO2 concentrations in subway cabin during the rush-hour were 1.3 and 1.45 times higher, respectively, than those of non rush-hour (p<0.05) in terms of geometric mean value. PM10 and CO2 concentration of express bus and train during the rush-hour also were 1.23 times higher than those of non rush-hour with relatively weak correlations (p=0.246). Among all PM10 concentrations, 16.9% and 3.8% of PM10 concentrations exceeded the IAQ guidelines (200 μg/m3 for non-rush hour and 250 μg/m3 for rush-hour), respectively. In terms of CO2 concentrations, 10.5% and 3.0% of them exceeded the IAQ guidelines (2,500 ppm for non rush-hour and 3,000 ppm for rush-hour), respectively. As a result, concentrations of PM10 and CO2 were estimated to be dominantly influenced by the operation characteristics of public transportation, such as degree of congestion and type of vehicle. In order to improve the IAQ of public transportation vehicles, specific air purification and ventilation systems are needed, depending on the characteristics of public transportation vehicles.

About this research paper

What this paper is about

In this study, we investigated the concentrations of PM10 and CO2 in public transportation vehicles (express bus, train, KTX, and subway) reported by previous indoor air quality (IAQ) surveys carried out from 2005 to 2013 in Korea. The number of valid data for PM10 was 566 and for CO2 was 579, and all data were classified according to whether it was collected during rush-hour or non rush-hour. PM10 and CO2 concentrations in subway cabin during the rush-hour were 1.3 and 1.45 times higher, respectively, than those of non rush-hour (p<0.05) in terms of geometric mean value. PM10 and CO2 concentration of express bus and train during the rush-hour also were 1.23 times higher than those of non rush-hour with relatively weak correlations (p=0.246). Among all PM10 concentrations, 16.9% and 3.8% of PM10 concentrations exceeded the IAQ guidelines (200 μg/m3 for non-rush hour and 250 μg/m3 for rush-hour), respectively. In terms of CO2 concentrations, 10.5% and 3.0% of them exceeded the IAQ guidelines (2,500 ppm for non rush-hour and 3,000 ppm for rush-hour), respectively. As a result, concentrations of PM10 and CO2 were estimated to be dominantly influenced by the operation characteristics of public transportation, such as degree of congestion and type of vehicle. In order to improve the IAQ of public transportation vehicles, specific air purification and ventilation systems are needed, depending on the characteristics of public transportation vehicles.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this study, we investigated the concentrations of PM10 and CO2 in public transportation vehicles (express bus, train, KTX, and subway) reported by previous indoor air quality (IAQ) surveys carried out from 2005 to 2013 in Korea. The number of valid data for PM10 was 566 and for CO2 was 579, and all data were classified according to whether it was collected during rush-hour or non rush-hour. PM10 and CO2 concentrations in subway cabin during the rush-hour were 1.3 and 1.45 times higher, respectively, than those of non rush-hour (p<0.05) in terms of geometric mean value. PM10 and CO2 concentration of express bus and train during the rush-hour also were 1.23 times higher than those of non rush-hour with relatively weak correlations (p=0.246). Among all PM10 concentrations, 16.9% and 3.8% of PM10 concentrations exceeded the IAQ guidelines (200 μg/m3 for non-rush hour and 250 μg/m3 for rush-hour), respectively. In terms of CO2 concentrations, 10.5% and 3.0% of them exceeded the IAQ guidelines (2,500 ppm for non rush-hour and 3,000 ppm for rush-hour), respectively. As a result, concentrations of PM10 and CO2 were estimated to be dominantly influenced by the operation characteristics of public transportation, such as degree of congestion and type of vehicle. In order to improve the IAQ of public transportation vehicles, specific air purification and ventilation systems are needed, depending on the characteristics of public transportation vehicles.

Key concepts: Rush hour, Public transport, Indoor air quality, Ventilation (architecture), Air quality index, Environmental science, Transport engineering, Environmental engineering

Back to paper searchBrowse research topicsOriginal source
혼잡영향에 따른 대중교통 차량 내 PM10과 CO2 농도 특성에 관한 연구 — Research Paper | ScholarLens