2016•Unpublished venueRequires access

Joint generation dispatching of power system with nuclear power units participating in peak load regulation

Wei Zhou, Shubo Hu, Hui Sun, Hong Gu, Jinsong Liu, Zhonghui John Wang

Open publisher page 9 citations

Abstract

With nuclear power generation increasing, power system peak load situation is becoming more and more serious. It is very important to study the joint generation dispatching issue of power grid for nuclear power peaking. Due to the anti peaking characteristics of wind power output, power load peak valley difference further increases, and thus it exacerbates the difficulty of peak load regulation in power grid. By increasing the capacity of heat storage device, the peak load regulation can be realized when nuclear power is regarded as the base load in power grid. A joint nuclear-thermal-wind-heat storage generation dispatching model is proposed in this paper according to the time transfer capability of heat storage device energy. It can achieve the equivalent peak power of nuclear power generation. Numerical results and analysis are given to demonstrate the feasibility of the joint generation dispatching model.

About this research paper

What this paper is about

With nuclear power generation increasing, power system peak load situation is becoming more and more serious. It is very important to study the joint generation dispatching issue of power grid for nuclear power peaking. Due to the anti peaking characteristics of wind power output, power load peak valley difference further increases, and thus it exacerbates the difficulty of peak load regulation in power grid. By increasing the capacity of heat storage device, the peak load regulation can be realized when nuclear power is regarded as the base load in power grid. A joint nuclear-thermal-wind-heat storage generation dispatching model is proposed in this paper according to the time transfer capability of heat storage device energy. It can achieve the equivalent peak power of nuclear power generation. Numerical results and analysis are given to demonstrate the feasibility of the joint generation dispatching model.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

With nuclear power generation increasing, power system peak load situation is becoming more and more serious. It is very important to study the joint generation dispatching issue of power grid for nuclear power peaking. Due to the anti peaking characteristics of wind power output, power load peak valley difference further increases, and thus it exacerbates the difficulty of peak load regulation in power grid. By increasing the capacity of heat storage device, the peak load regulation can be realized when nuclear power is regarded as the base load in power grid. A joint nuclear-thermal-wind-heat storage generation dispatching model is proposed in this paper according to the time transfer capability of heat storage device energy. It can achieve the equivalent peak power of nuclear power generation. Numerical results and analysis are given to demonstrate the feasibility of the joint generation dispatching model.

Key concepts: Base load power plant, Nuclear power, Power (physics), Electricity generation, Joint (building), Wind power, Electric power system, Peak load

Related papers

Back to paper searchBrowse research topicsOriginal source
Joint generation dispatching of power system with nuclear power units participating in peak load regulation — Research Paper | ScholarLens