2017The Journal of Trauma: Injury, Infection, and Critical CareRequires access

Minimal variation in anti-A and -B titers among healthy volunteers over time

Ulrik Sprogøe, Mark H. Yazer, Mads H. Rasmussen, Berit Antonsen, Claus Bistrup, Kristian Assing

Open publisher page 33 citations

Abstract

BACKGROUND: Using potentially out-of-group blood components, like low titer A plasma and O whole blood, in the resuscitation of trauma patients is becoming increasingly popular. However, very little is known whether the donors' anti-A and/or anti-B titers change over time and whether repeated titer measurements on the same donor are required to ensure that each donation produces a low titer product. METHODS: The anti-A and/or anti-B titers were measured on 56 healthy adult volunteers (47 blood donors; nine blood center personnel) every 3 months for 12 consecutive months using an automated solid phase analyzer. The results were expressed as log2 titer steps (e.g., titer 32 = 5 titer steps). RESULTS: Minor variations in the average anti-A and/or anti-B titers were seen over time; the maximum individual SD in each group was 1.50 (IgG anti-A) or 1.00 (IgM anti-A, IgM, and IgG anti-B). When the SDs for the four titer measurements from all 56 volunteers were combined as appropriate, the highest overall combined SD was 0.47 titer steps for IgG anti-A. This value corresponds to a 95% confidence interval for intraindividual variation in this antibody's titer over 12 months of 0.96 titer steps. Thus, based on one measurement, an IgG anti-A with a titer step of, for example, 6 would be expected to be in the range of titer step 5 to titer step 7 over the course of 1 year with 95% probability. CONCLUSION: The titers of anti-A and/or anti-B among healthy adults are stable over at least 1 year. This suggests that repeated titer measurements within a year on the same donor are not necessary if donations are made at 3 months or longer intervals. LEVEL OF EVIDENCE: Diagnostic study, level V.

About this research paper

What this paper is about

BACKGROUND: Using potentially out-of-group blood components, like low titer A plasma and O whole blood, in the resuscitation of trauma patients is becoming increasingly popular. However, very little is known whether the donors' anti-A and/or anti-B titers change over time and whether repeated titer measurements on the same donor are required to ensure that each donation produces a low titer product. METHODS: The anti-A and/or anti-B titers were measured on 56 healthy adult volunteers (47 blood donors; nine blood center personnel) every 3 months for 12 consecutive months using an automated solid phase analyzer. The results were expressed as log2 titer steps (e.g., titer 32 = 5 titer steps). RESULTS: Minor variations in the average anti-A and/or anti-B titers were seen over time; the maximum individual SD in each group was 1.50 (IgG anti-A) or 1.00 (IgM anti-A, IgM, and IgG anti-B). When the SDs for the four titer measurements from all 56 volunteers were combined as appropriate, the highest overall combined SD was 0.47 titer steps for IgG anti-A. This value corresponds to a 95% confidence interval for intraindividual variation in this antibody's titer over 12 months of 0.96 titer steps. Thus, based on one measurement, an IgG anti-A with a titer step of, for example, 6 would be expected to be in the range of titer step 5 to titer step 7 over the course of 1 year with 95% probability. CONCLUSION: The titers of anti-A and/or anti-B among healthy adults are stable over at least 1 year. This suggests that repeated titer measurements within a year on the same donor are not necessary if donations are made at 3 months or longer intervals. LEVEL OF EVIDENCE: Diagnostic study, level V.

Why it matters

OpenAlex reports 33 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Using potentially out-of-group blood components, like low titer A plasma and O whole blood, in the resuscitation of trauma patients is becoming increasingly popular. However, very little is known whether the donors' anti-A and/or anti-B titers change over time and whether repeated titer measurements on the same donor are required to ensure that each donation produces a low titer product. METHODS: The anti-A and/or anti-B titers were measured on 56 healthy adult volunteers (47 blood donors; nine blood center personnel) every 3 months for 12 consecutive months using an automated solid phase analyzer. The results were expressed as log2 titer steps (e.g., titer 32 = 5 titer steps). RESULTS: Minor variations in the average anti-A and/or anti-B titers were seen over time; the maximum individual SD in each group was 1.50 (IgG anti-A) or 1.00 (IgM anti-A, IgM, and IgG anti-B). When the SDs for the four titer measurements from all 56 volunteers were combined as appropriate, the highest overall combined SD was 0.47 titer steps for IgG anti-A. This value corresponds to a 95% confidence interval for intraindividual variation in this antibody's titer over 12 months of 0.96 titer steps. Thus, based on one measurement, an IgG anti-A with a titer step of, for example, 6 would be expected to be in the range of titer step 5 to titer step 7 over the course of 1 year with 95% probability. CONCLUSION: The titers of anti-A and/or anti-B among healthy adults are stable over at least 1 year. This suggests that repeated titer measurements within a year on the same donor are not necessary if donations are made at 3 months or longer intervals. LEVEL OF EVIDENCE: Diagnostic study, level V.

Key concepts: Variation (astronomy), Titer, Medicine, Immunology, Antibody, Physics, Astrophysics

Related papers

Back to paper searchBrowse research topicsOriginal source
Minimal variation in anti-A and -B titers among healthy volunteers over time — Research Paper | ScholarLens