Improvement in the Quality of HbA1c Determination by Using Commutable Specimens With IFCC-Assigned Values

Rui Zhou, Zhiqi Gao, Qing Tong, Chang Zuo, Zhixin Song, Wei Wang, Qingtao Wang

Open full text 1 citations

Abstract

BACKGROUND: To assess the usefulness of commutable secondary reference materials with International Federation of Clinical Chemistry (IFCC)-assigned values, for improving the quality of hemoglobin A1c (HbA 1c ) determination. METHODS: We recalibrated and evaluated 3 point-of-care-test (POCT) devices via 3 different method-specific central laboratory analyzers that were calibrated using commutable specimens with IFCC-assigned values. The staff members who performed POCT were also evaluated before and after training. RESULTS: HbA 1c levels measured with POCT devices showed significantly lesser bias after external mathematical calibration. The interlaboratory CVs for HbA 1c measurements decreased from 12% to 4% after training of POCT-device-operating personnel in the NycoCard group. The CVs in the DCA Vantage and Afinion groups also improved after training. CONCLUSION: Calibration of laboratory devices by specimens with IFCC-assigned values and by external mathematical calibration could improve the accuracy of POCT HbA 1c measurements. Also, standardized training could improve precision in POCT HbA 1c measurements, especially for semiautomated HbA 1c POCT devices.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: To assess the usefulness of commutable secondary reference materials with International Federation of Clinical Chemistry (IFCC)-assigned values, for improving the quality of hemoglobin A1c (HbA 1c ) determination. METHODS: We recalibrated and evaluated 3 point-of-care-test (POCT) devices via 3 different method-specific central laboratory analyzers that were calibrated using commutable specimens with IFCC-assigned values. The staff members who performed POCT were also evaluated before and after training. RESULTS: HbA 1c levels measured with POCT devices showed significantly lesser bias after external mathematical calibration. The interlaboratory CVs for HbA 1c measurements decreased from 12% to 4% after training of POCT-device-operating personnel in the NycoCard group. The CVs in the DCA Vantage and Afinion groups also improved after training. CONCLUSION: Calibration of laboratory devices by specimens with IFCC-assigned values and by external mathematical calibration could improve the accuracy of POCT HbA 1c measurements. Also, standardized training could improve precision in POCT HbA 1c measurements, especially for semiautomated HbA 1c POCT devices.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: To assess the usefulness of commutable secondary reference materials with International Federation of Clinical Chemistry (IFCC)-assigned values, for improving the quality of hemoglobin A1c (HbA 1c ) determination. METHODS: We recalibrated and evaluated 3 point-of-care-test (POCT) devices via 3 different method-specific central laboratory analyzers that were calibrated using commutable specimens with IFCC-assigned values. The staff members who performed POCT were also evaluated before and after training. RESULTS: HbA 1c levels measured with POCT devices showed significantly lesser bias after external mathematical calibration. The interlaboratory CVs for HbA 1c measurements decreased from 12% to 4% after training of POCT-device-operating personnel in the NycoCard group. The CVs in the DCA Vantage and Afinion groups also improved after training. CONCLUSION: Calibration of laboratory devices by specimens with IFCC-assigned values and by external mathematical calibration could improve the accuracy of POCT HbA 1c measurements. Also, standardized training could improve precision in POCT HbA 1c measurements, especially for semiautomated HbA 1c POCT devices.

Key concepts: Point-of-care testing, Calibration, External quality assessment, Medical laboratory, Medicine, Pathology, Mathematics, Statistics

Related papers

Back to paper searchBrowse research topicsOriginal source
Improvement in the Quality of HbA1c Determination by Using Commutable Specimens With IFCC-Assigned Values — Research Paper | ScholarLens