Numerical Investigation on Solar Absorption Chiller with LiBr-H2O Operating Conditions and Performances
Raluca Porumb, Bogdan Porumb, Mugur C. Bălan
Abstract
Open-access reader
Raluca Porumb, Bogdan Porumb, Mugur C. Bălan
Abstract
Open-access reader
The study presents a numerical investigation on operating conditions and performances of a solar absorption chiller with LiBr-H 2 O. The working cycle of the investigated solar cooling equipment was modelled based on thermodynamic principles by the use of the software platform Engineering Equation Solver and was validated based on similar studies reported in literature. Further it was investigated the influence of the operating conditions like solar hot water temperature, cooling water temperature and cold water temperature, on the coefficient of performance of the solar absorption chiller and on the conditions of crystallisation. The numerical model of the solar absorption chiller working cycle proved to be capable to describe the behaviour of the equipment and to evaluate the safe operating conditions from the crystallisation point of view and from degassing point of view.
OpenAlex reports 37 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The study presents a numerical investigation on operating conditions and performances of a solar absorption chiller with LiBr-H 2 O. The working cycle of the investigated solar cooling equipment was modelled based on thermodynamic principles by the use of the software platform Engineering Equation Solver and was validated based on similar studies reported in literature. Further it was investigated the influence of the operating conditions like solar hot water temperature, cooling water temperature and cold water temperature, on the coefficient of performance of the solar absorption chiller and on the conditions of crystallisation. The numerical model of the solar absorption chiller working cycle proved to be capable to describe the behaviour of the equipment and to evaluate the safe operating conditions from the crystallisation point of view and from degassing point of view.
Key concepts: Absorption refrigerator, Chiller, Coefficient of performance, Solar air conditioning, Solver, Process engineering, Thermodynamics, Nuclear engineering