2016Unpublished venueRequires access

Comparison of radialis sphygmomanometer in evaluating the blood pressure of healthy volunteers

Hendi Handian Rachmat

Open publisher page 4 citations

Abstract

In this study, we compared the blood pressure measurement that obtained by a radialis sphygmomanometer with two others non-invasive sphygmomanometer types i.e. an aneroid sphygmomanometer and a brachial sphygmomanometer. The aim of this study was to evaluate statistically the blood pressure values of a radialis sphygmomanometer relative two other types of sphygmomanometer. This study was performed as a validation test before modifying the existing display-based radialis sphygmomanometer to a voice-based radialis sphygmomanometer. By developing the radialis sphygmomanometer with voice output, we believed that a blind people can be possible to measure the blood pressure easily, independently and periodically. To collect the data measurements, an experience nurse measured two blood pressure values i.e. systolic and diastolic of 30 healthy adult volunteers (17 female, 13 male; mean age 40.87±13.97 years, range: 16-75 years) with three diffent types of sphygmomanometer. A mercury sphygmomanometer was used at first and continued by a brachial sphygmomanometer and a radialis sphygmomanometer in order. Data were then analyzed statically using one way ANOVA in SPSS 18. The statistic results showed that the average measurement values were equal among three types of sphygmomanometer with significance (α) of systole and diastole bigger than 0.05 i.e. 0.055 and 0.178, respectively.

About this research paper

What this paper is about

In this study, we compared the blood pressure measurement that obtained by a radialis sphygmomanometer with two others non-invasive sphygmomanometer types i.e. an aneroid sphygmomanometer and a brachial sphygmomanometer. The aim of this study was to evaluate statistically the blood pressure values of a radialis sphygmomanometer relative two other types of sphygmomanometer. This study was performed as a validation test before modifying the existing display-based radialis sphygmomanometer to a voice-based radialis sphygmomanometer. By developing the radialis sphygmomanometer with voice output, we believed that a blind people can be possible to measure the blood pressure easily, independently and periodically. To collect the data measurements, an experience nurse measured two blood pressure values i.e. systolic and diastolic of 30 healthy adult volunteers (17 female, 13 male; mean age 40.87±13.97 years, range: 16-75 years) with three diffent types of sphygmomanometer. A mercury sphygmomanometer was used at first and continued by a brachial sphygmomanometer and a radialis sphygmomanometer in order. Data were then analyzed statically using one way ANOVA in SPSS 18. The statistic results showed that the average measurement values were equal among three types of sphygmomanometer with significance (α) of systole and diastole bigger than 0.05 i.e. 0.055 and 0.178, respectively.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this study, we compared the blood pressure measurement that obtained by a radialis sphygmomanometer with two others non-invasive sphygmomanometer types i.e. an aneroid sphygmomanometer and a brachial sphygmomanometer. The aim of this study was to evaluate statistically the blood pressure values of a radialis sphygmomanometer relative two other types of sphygmomanometer. This study was performed as a validation test before modifying the existing display-based radialis sphygmomanometer to a voice-based radialis sphygmomanometer. By developing the radialis sphygmomanometer with voice output, we believed that a blind people can be possible to measure the blood pressure easily, independently and periodically. To collect the data measurements, an experience nurse measured two blood pressure values i.e. systolic and diastolic of 30 healthy adult volunteers (17 female, 13 male; mean age 40.87±13.97 years, range: 16-75 years) with three diffent types of sphygmomanometer. A mercury sphygmomanometer was used at first and continued by a brachial sphygmomanometer and a radialis sphygmomanometer in order. Data were then analyzed statically using one way ANOVA in SPSS 18. The statistic results showed that the average measurement values were equal among three types of sphygmomanometer with significance (α) of systole and diastole bigger than 0.05 i.e. 0.055 and 0.178, respectively.

Key concepts: Sphygmomanometer, Blood pressure, Medicine, Internal medicine, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of radialis sphygmomanometer in evaluating the blood pressure of healthy volunteers — Research Paper | ScholarLens